PlainWater
StatesUtah

Community Water System · PWS UTAH25008

American Fork City

Lehi, Utah 84043 - drinking water served from groundwater sources to 39,045 people, tracked in EPA SDWIS and UCMR5.

39,045
People served
103
EPA violations
17
Health-based
No PFAS
UCMR5 result

The verdict

EPA records 103 drinking-water violations at American Fork City, 17% of them health-based - below the Utah per-system average.

103
Total EPA violations on record
17%
Health-based (MCL / treatment failure)
39,045
People served by this system
0
PFAS compounds detected (UCMR5)

Water Quality Snapshot: American Fork City

American Fork City is a local-owned community water system that delivers drinking water to 39,045 residents in Lehi, Utah (Utah County) through 11,923 service connections. Its water is drawn from groundwater sources. EPA's Safe Drinking Water Information System records 103 total violations for this system , of which 17 (17%) are health-based, meaning a contaminant exceeded an EPA Maximum Contaminant Level or a required treatment technique failed. A further 62 monitoring and reporting violations are on file. The most recent violation on record dates to 2025.

The most frequently cited contaminant at this system is Nitrate, recorded in 19 violations (MR). This system was sampled under EPA's UCMR5 PFAS monitoring program and no PFAS compounds were detected above the minimum reporting level.

Across Utah, EPA tracks 1,068 public water systems serving 3,870,776 people, with 169,784 cumulative violations and 10,671 health-based violations on record. About 98% of systems in the state carry at least one violation, and state-wide the average per system is 159 violations. Statewide, 91 of 129 UCMR5-tested systems have reported PFAS detections (70.5%).

American Fork City's 103 violations sit below the Utah average.

All figures above are sourced directly from EPA SDWIS and UCMR5 public data releases and are updated as EPA publishes new reporting cycles.

Population Served
39,045
Total Violations
103
Health-Based Violations
17
Water Source
Groundwater

System Details

System Type
Community
Owner Type
Local
Connections
11,923
County
Utah
School/Daycare
No
MCL Violations
17
Monitoring Violations
62
Treatment Tech Violations
0

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Nitrate MR 19 2008
Coliform (TCR) MCL 17 2015
Radium-228 MR 12 2009
E. COLI MR 9 2014
Chlorine MR 6 2011
TTHM MR 4 2011
Total Haloacetic Acids (HAA5) MR 4 2011
Consumer Confidence Rule Other 2 2025
Gross Alpha, Excl. Radon and U MR 1 1988
Chromium MR 1 1988
Fluoride MR 1 1988
Mercury MR 1 1988
Cadmium MR 1 1988
Arsenic MR 1 1988
Barium MR 1 1988
Selenium MR 1 1988

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 0 of 348 samples detected PFAS.

Contaminant Date Result MRL Status
HFPO-DA 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
PFTrDA 8/19/2024 <7.00 ppt 7.00 ppt Not Detected
PFTA 8/19/2024 <8.00 ppt 8.00 ppt Not Detected
PFHpS 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeS 8/19/2024 <4.00 ppt 4.00 ppt Not Detected
NFDHA 8/19/2024 <20.00 ppt 20.00 ppt Not Detected
PFEESA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFMBA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFMPA 8/19/2024 <4.00 ppt 4.00 ppt Not Detected
8:2 FTS 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
4:2 FTS 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFBS 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFBA 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
NMeFOSAA 8/19/2024 <6.00 ppt 6.00 ppt Not Detected
ADONA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
9Cl-PF3ONS 8/19/2024 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
PFUnA 8/19/2024 <2.00 ppt 2.00 ppt Not Detected
PFHxA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFDA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFOA 8/19/2024 <4.00 ppt 4.00 ppt Not Detected
PFOS 8/19/2024 <4.00 ppt 4.00 ppt Not Detected
PFNA 8/19/2024 <4.00 ppt 4.00 ppt Not Detected
PFHxS 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFHpA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
6:2 FTS 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
NEtFOSAA 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
PFBA 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
HFPO-DA 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
ADONA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
9Cl-PF3ONS 8/19/2024 <2.00 ppt 2.00 ppt Not Detected
6:2 FTS 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
11Cl-PF3OUdS 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
PFUnA 8/19/2024 <2.00 ppt 2.00 ppt Not Detected
4:2 FTS 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
NEtFOSAA 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
PFDA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
8:2 FTS 8/19/2024 <5.00 ppt 5.00 ppt Not Detected
PFMPA 8/19/2024 <4.00 ppt 4.00 ppt Not Detected
PFPeA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFMBA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFEESA 8/19/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeS 8/19/2024 <4.00 ppt 4.00 ppt Not Detected
PFTrDA 8/19/2024 <7.00 ppt 7.00 ppt Not Detected
NMeFOSAA 8/19/2024 <6.00 ppt 6.00 ppt Not Detected
PFOA 8/19/2024 <4.00 ppt 4.00 ppt Not Detected

Verify This Water System

The figures above are aggregated from EPA's public databases. To verify the underlying records, or to file a complaint, request a Consumer Confidence Report, or check current monitoring status, go directly to the federal and state regulators that enforce the Safe Drinking Water Act for American Fork City.

Federal Source of Truth

EPA SDWIS, Federal Reports

EPA's Safe Drinking Water Information System (SDWIS) holds the federal compliance record for every regulated public water system. Open the system-level report by PWS ID:

View PWS ID UTAH25008 on SDWIS

Source: EPA SDWIS Federal Reports Search

State Regulator

Utah Drinking Water Authority

Utah's primacy agency administers the Safe Drinking Water Act locally. Search EPA SDWIS for the current state contact, or use the state's public health or environment department portal.

Find UT regulator via EPA SDWIS

Violation Timeline

Each row links to the EPA SDWIS public record for verification. Cross-reference the contaminant code on EPA's federal report to see violation dates, return-to-compliance status, and enforcement actions.

Year (latest) Contaminant Category Count EPA Record
2025 Consumer Confidence Rule Other 2 SDWIS / UTAH25008 / 7000
2015 Coliform (TCR) MCL 17 SDWIS / UTAH25008 / 3100
2014 E. COLI MR 9 SDWIS / UTAH25008 / 3014
2011 Chlorine MR 6 SDWIS / UTAH25008 / 0999
2011 TTHM MR 4 SDWIS / UTAH25008 / 2950
2011 Total Haloacetic Acids (HAA5) MR 4 SDWIS / UTAH25008 / 2456
2009 Radium-228 MR 12 SDWIS / UTAH25008 / 4030
2008 Nitrate MR 19 SDWIS / UTAH25008 / 1040
1988 Gross Alpha, Excl. Radon and U MR 1 SDWIS / UTAH25008 / 4000
1988 Chromium MR 1 SDWIS / UTAH25008 / 1020
1988 Fluoride MR 1 SDWIS / UTAH25008 / 1025
1988 Mercury MR 1 SDWIS / UTAH25008 / 1035
1988 Cadmium MR 1 SDWIS / UTAH25008 / 1015
1988 Arsenic MR 1 SDWIS / UTAH25008 / 1005
1988 Barium MR 1 SDWIS / UTAH25008 / 1010

How American Fork City Compares

Cross-reference this system's record against state averages and the federal MCL framework for context.

Metric American Fork City Utah avg Federal benchmark
Total violations 103 159 SDWA compliance, any non-zero count is a recorded breach
Health-based violations 17 10 Indicates a contaminant exceeded a federal MCL
PFAS detection None 70.5% EPA final rule (2024): PFOA/PFOS MCL = 4.0 ppt
Population served 39,045 3,624 Sizing context for compliance burden

Sources: EPA SDWIS and EPA National Primary Drinking Water Regulations (40 CFR Part 141). State averages computed across 1,068 regulated public water systems in Utah.

Federal MCL reference, Safe Drinking Water Act thresholds
Contaminant Federal MCL / Action Level Note
Lead 0 mg/L (Action Level: 0.015 mg/L) Lead and Copper Rule treatment technique
Arsenic 0.010 mg/L (10 ppb) Health-based MCL since 2006
Total Coliform Treatment technique (RTCR) Indicator organism, monitoring trigger
PFOA / PFOS (PFAS) 4.0 ppt each (final 2024 rule) Compliance deadline 2029 (EPA proposed extending to 2031, not yet final as of May 2026)
Nitrate (as N) 10 mg/L Acute health risk for infants

Frequently Asked Questions

Is American Fork City water safe to drink?
American Fork City (PWS ID: UTAH25008) has 103 recorded violations in the EPA SDWIS database. No PFAS contamination was detected in UCMR5 testing. This system serves 39,045 people using Groundwater sources.
How many people does American Fork City serve?
American Fork City serves 39,045 people in Lehi, Utah. It is a Local-owned system using Groundwater water sources with 11,923 service connections.
What type of violations does American Fork City have?
American Fork City has 103 total violations: 17 health-based violations (MCL exceedances or treatment failures), 62 monitoring/reporting violations, and 0 treatment technique violations. Health-based violations indicate contaminant levels exceeded EPA safe limits.
Has PFAS been detected in American Fork City water?
No. American Fork City was tested for PFAS under the EPA's UCMR5 monitoring program and no PFAS contamination was detected.
What water source does American Fork City use?
American Fork City uses Groundwater as its primary water source. It is classified as a Community Water System (CWS), serving residential populations year-round.
Where does this data come from?
All data comes from the EPA Safe Drinking Water Information System (SDWIS) and the UCMR5 PFAS monitoring program. SDWIS tracks compliance for all public water systems regulated under the Safe Drinking Water Act.
Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. PFAS data from EPA UCMR5 monitoring program (2023-2025). This data is provided for informational purposes only.
Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater Editorial

Every figure on PlainWater is rendered directly from EPA SDWIS drinking-water data, no number is typed in by an editor. This system's figures are rendered directly from EPA SDWIS data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.