PlainWater

Community Water System · PWS TN0000548

Pigeon Forge Water Department

Operator location Sevierville, Tennessee - larger served population (> 3,309) at 14,872 people served; 41 SDWIS violations on record from surface water sources.

14,872
People served (this PWS)
41
EPA violations (this PWS)
3
Health-based (this PWS)
No PFAS
UCMR5 (this PWS)
Follow published updates (RSS)

Pigeon Forge Water Department standing, mid SDWIS violation third

14,872 people served (SDWIS) - larger served population (> 3,309). Corpus terciles use 29,740 systems serving 500+ (the sitemap cohort). Health-based share 7% is middle-third health share (≤ 23%). UCMR5: UCMR5 tested, none detected. Population rank #3,492 of 29,740 among systems serving 500+.

The verdict

Pigeon Forge Water Department lands in the middle third by violation volume (41), large enough for peer comparisons without matching the fleet's heaviest ledgers. Population served is large (14,872; larger served population (> 3,309)), so household exposure scale sits behind the violation mix. Health-based share is 7% (middle-third health share (≤ 23%)). UCMR5 tested this system and reported no PFAS above the minimum reporting level.

#3,492 of 29,740
Population · /systems
#106 of 436
Population · TN
41
Total EPA violations on record
7%
Health-based (MCL / treatment failure)

Population ordinals match the sitemap cohort (systems serving 500+, population_served DESC). See methodology · corpus placement.

System Details

System Type
Community
Owner Type
Local
Connections
5,832
County
Sevier
School/Daycare
No
MCL Violations
0
Monitoring Violations
35
Treatment Tech Violations
3

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Coliform (TCR) MR 4 1998
TTHM MR 4 2008
Total Haloacetic Acids (HAA5) MR 4 2008
Long Term 2 Enhanced Surface Water Treatment Rule TT 3 2010
Nitrate MR 2 2004
Gross Alpha, Excl. Radon and U MR 1 1984
Benzene MR 1 1989
1,2-Dichloroethane MR 1 1989
1,1-Dichloroethylene MR 1 1989
1,1,1-Trichloroethane MR 1 1989
CHLOROBENZENE MR 1 1989
cis-1,2-Dichloroethylene MR 1 1989
trans-1,2-Dichloroethylene MR 1 1989
DICHLOROMETHANE MR 1 1989
1,2-Dichloropropane MR 1 1989
Ethylbenzene MR 1 1989
Styrene MR 1 1989
Tetrachloroethylene MR 1 1989
Toluene MR 1 1989
1,1,2-Trichloroethane MR 1 1989
o-Dichlorobenzene MR 1 1989
p-Dichlorobenzene MR 1 1989
Carbon tetrachloride MR 1 1989
1,2,4-Trichlorobenzene MR 1 1989
Trichloroethylene MR 1 1989
Vinyl chloride MR 1 1989

Violation Count vs. the National Corpus

Pigeon Forge Water Department has 41 recorded EPA violations, 51% of the 29,740 public water systems serving 500+ people nationwide carry fewer, and 48% carry more. 7% of this system's own violations are health-based (3 of 41), and it ranks #3,492 of 29,740 by population served among that same cohort.

EPA violations vs. the national water-system corpus

Public water systems serving 500+ people (EPA SDWIS)

41 Around the middle fewer violations than 48% of 29,740 water systems

the national water-system corpus, bucketed by value

Each bar is a band; taller bars hold more water systems. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source EPA SDWIS · 2026-05-15

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 0 of 116 samples detected PFAS.

Contaminant Date Result MRL Status
8:2 FTS 8/9/2023 <5.00 ppt 5.00 ppt Not Detected
9Cl-PF3ONS 8/9/2023 <2.00 ppt 2.00 ppt Not Detected
PFTA 8/9/2023 <8.00 ppt 8.00 ppt Not Detected
PFHpS 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeS 8/9/2023 <4.00 ppt 4.00 ppt Not Detected
NFDHA 8/9/2023 <20.00 ppt 20.00 ppt Not Detected
PFEESA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFMBA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFMPA 8/9/2023 <4.00 ppt 4.00 ppt Not Detected
4:2 FTS 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
6:2 FTS 8/9/2023 <5.00 ppt 5.00 ppt Not Detected
PFBA 8/9/2023 <5.00 ppt 5.00 ppt Not Detected
PFTrDA 8/9/2023 <7.00 ppt 7.00 ppt Not Detected
ADONA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
11Cl-PF3OUdS 8/9/2023 <5.00 ppt 5.00 ppt Not Detected
PFUnA 8/9/2023 <2.00 ppt 2.00 ppt Not Detected
PFHxA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFDoA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFDA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFOA 8/9/2023 <4.00 ppt 4.00 ppt Not Detected
PFOS 8/9/2023 <4.00 ppt 4.00 ppt Not Detected
PFNA 8/9/2023 <4.00 ppt 4.00 ppt Not Detected
PFHxS 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFHpA 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
PFBS 8/9/2023 <3.00 ppt 3.00 ppt Not Detected
HFPO-DA 8/9/2023 <5.00 ppt 5.00 ppt Not Detected
NMeFOSAA 8/9/2023 <6.00 ppt 6.00 ppt Not Detected
NEtFOSAA 8/9/2023 <5.00 ppt 5.00 ppt Not Detected
6:2 FTS 5/7/2024 <5.00 ppt 5.00 ppt Not Detected
PFBA 5/7/2024 <5.00 ppt 5.00 ppt Not Detected
HFPO-DA 5/7/2024 <5.00 ppt 5.00 ppt Not Detected
PFBS 5/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFHpA 5/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxS 5/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFNA 5/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFOS 5/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFOA 5/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFDA 5/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 5/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxA 5/7/2024 <3.00 ppt 3.00 ppt Not Detected
8:2 FTS 5/7/2024 <5.00 ppt 5.00 ppt Not Detected
11Cl-PF3OUdS 5/7/2024 <5.00 ppt 5.00 ppt Not Detected
PFPeS 5/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFTrDA 5/7/2024 <7.00 ppt 7.00 ppt Not Detected
NEtFOSAA 5/7/2024 <5.00 ppt 5.00 ppt Not Detected
NMeFOSAA 5/7/2024 <6.00 ppt 6.00 ppt Not Detected
ADONA 5/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFUnA 5/7/2024 <2.00 ppt 2.00 ppt Not Detected
PFHpS 5/7/2024 <3.00 ppt 3.00 ppt Not Detected

Population served record for Pigeon Forge Water Department

EPA SDWIS lists 14,872 people served and 5,832 connections for this PWS, confirm the service-area footprint on the federal report before comparing to municipal census totals.

Sources: EPA SDWIS · Tennessee Department of Environment & Conservation, Drinking Water

Nationwide peers

41 violations · 14,872 served: nearest cross-state SDWIS matches.

Cross-state systems near this violation count

Nearest cross-state community systems (500+ served) by total SDWIS violations on record.

4 peers

Cross-state systems with similar served population

Nearest cross-state systems by EPA SDWIS population_served (same 500+ sitemap gate).

4 peers

What to do with Pigeon Forge Water Department

Use this system's EPA-reported record as a starting filter, not a final verdict.

  • See how every tracked system in Tennessee compares on the same EPA violation measures. Tennessee systems
  • Check whether PFAS was detected at this system under UCMR5 testing. PFAS guide
  • Find and compare another public water system by name or PWSID. Search systems

EPA SDWIS and UCMR5 figures are informational only, not a substitute for a certified lab test of your own tap water.

Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater