PlainWater

Community Water System · PWS PA1090069

Warminster Municipal Authority

Warminster, Pennsylvania 18974 - drinking water served from surface water sources to 40,000 people, tracked in EPA SDWIS and UCMR5.

40,000
People served
2,250
EPA violations
1
Health-based
2 PFAS
UCMR5 result

The verdict

EPA records 2,250 drinking-water violations at Warminster Municipal Authority - above the Pennsylvania per-system average, and UCMR5 testing detected 2 PFAS compounds.

2,250
Total EPA violations on record
0%
Health-based (MCL / treatment failure)
40,000
People served by this system
2
PFAS compounds detected (UCMR5)

Water Quality Snapshot: Warminster Municipal Authority

Warminster Municipal Authority is a local-owned community water system that delivers drinking water to 40,000 residents in Warminster, Pennsylvania (Bucks County) through 10,369 service connections. Its water is drawn from surface water sources. EPA's Safe Drinking Water Information System records 2,250 total violations for this system , of which 1 (0%) are health-based, meaning a contaminant exceeded an EPA Maximum Contaminant Level or a required treatment technique failed. A further 2,219 monitoring and reporting violations are on file. The most recent violation on record dates to 2024.

The most frequently cited contaminant at this system is Simazine, recorded in 135 violations (MR). Under EPA's UCMR5 PFAS monitoring program, 2 PFAS compounds were detected in samples collected from this system, with a maximum reported concentration of 28.5 ppt (parts per trillion). PFAS are persistent synthetic chemicals linked to health effects at very low exposure levels.

Across Pennsylvania, EPA tracks 7,701 public water systems serving 12,630,061 people, with 1,159,868 cumulative violations and 68,517 health-based violations on record. About 97% of systems in the state carry at least one violation, and state-wide the average per system is 150.6 violations. Statewide, 224 of 389 UCMR5-tested systems have reported PFAS detections (57.6%).

Warminster Municipal Authority's 2,250 violations sit above the Pennsylvania average.

All figures above are sourced directly from EPA SDWIS and UCMR5 public data releases and are updated as EPA publishes new reporting cycles.

PFAS Detected

2 PFAS "forever chemicals" detected in testing under EPA's UCMR5 monitoring program.

Population Served
40,000
Total Violations
2,250
Health-Based Violations
1
Water Source
Surface Water

System Details

System Type
Community
Owner Type
Local
Connections
10,369
County
Bucks
School/Daycare
No
MCL Violations
1
Monitoring Violations
2,219
Treatment Tech Violations
0

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Simazine MR 135 2003
LASSO MR 131 2003
BHC-GAMMA MR 129 2003
Methoxychlor MR 129 2003
ETHYLENE DIBROMIDE MR 128 2003
Atrazine MR 103 2003
Xylenes, Total MR 62 2007
p-Dichlorobenzene MR 62 2007
1,1-Dichloroethylene MR 62 2007
1,2-Dichloroethane MR 62 2007
Carbon tetrachloride MR 62 2007
Benzene MR 62 2007
1,2,4-Trichlorobenzene MR 61 2007
o-Dichlorobenzene MR 61 2007
1,1,1-Trichloroethane MR 61 2007
1,2-Dichloropropane MR 61 2007
CHLOROBENZENE MR 61 2007
Styrene MR 61 2007
trans-1,2-Dichloroethylene MR 61 2007
Trichloroethylene MR 61 2007
1,1,2-Trichloroethane MR 61 2007
Tetrachloroethylene MR 61 2007
Toluene MR 61 2007
Ethylbenzene MR 61 2007
DICHLOROMETHANE MR 61 2007
cis-1,2-Dichloroethylene MR 61 2007
OXAMYL MR 44 2003
1,2-DIBROMO-3-CHLOROPROPANE MR 34 2003
Radium-226 MR 33 2005
Radium-228 MR 33 2005

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 8 of 232 samples detected PFAS.

Contaminant Date Result MRL Status
PFTrDA 8/2/2023 <7.00 ppt 7.00 ppt Not Detected
NEtFOSAA 8/2/2023 <5.00 ppt 5.00 ppt Not Detected
NMeFOSAA 8/2/2023 <6.00 ppt 6.00 ppt Not Detected
PFTA 8/2/2023 <8.00 ppt 8.00 ppt Not Detected
PFNA 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
HFPO-DA 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
ADONA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
9Cl-PF3ONS 5/17/2023 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
PFUnA 5/17/2023 <2.00 ppt 2.00 ppt Not Detected
PFHxA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFDoA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFDA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFOS 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
PFHpA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFHxS 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFBA 5/17/2023 12.90 ppt 5.00 ppt Detected
PFOA 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
PFTA 5/17/2023 <8.00 ppt 8.00 ppt Not Detected
PFBS 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
6:2 FTS 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
PFTrDA 5/17/2023 <7.00 ppt 7.00 ppt Not Detected
NMeFOSAA 5/17/2023 <6.00 ppt 6.00 ppt Not Detected
PFHpS 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeS 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
NFDHA 5/17/2023 <20.00 ppt 20.00 ppt Not Detected
PFEESA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFMBA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeA 5/17/2023 3.70 ppt 3.00 ppt Detected
PFMPA 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
8:2 FTS 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
4:2 FTS 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
NEtFOSAA 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
PFMBA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
HFPO-DA 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
PFBA 5/17/2023 8.70 ppt 5.00 ppt Detected
6:2 FTS 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
4:2 FTS 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
8:2 FTS 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
PFEESA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeA 5/17/2023 21.70 ppt 3.00 ppt Detected
ADONA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected
PFNA 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
NFDHA 5/17/2023 <20.00 ppt 20.00 ppt Not Detected
PFPeS 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
PFMPA 5/17/2023 <4.00 ppt 4.00 ppt Not Detected
9Cl-PF3ONS 5/17/2023 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 5/17/2023 <5.00 ppt 5.00 ppt Not Detected
PFUnA 5/17/2023 <2.00 ppt 2.00 ppt Not Detected
PFHxA 5/17/2023 <3.00 ppt 3.00 ppt Not Detected

Verify This Water System

The figures above are aggregated from EPA's public databases. To verify the underlying records, or to file a complaint, request a Consumer Confidence Report, or check current monitoring status, go directly to the federal and state regulators that enforce the Safe Drinking Water Act for Warminster Municipal Authority.

Federal Source of Truth

EPA SDWIS, Federal Reports

EPA's Safe Drinking Water Information System (SDWIS) holds the federal compliance record for every regulated public water system. Open the system-level report by PWS ID:

View PWS ID PA1090069 on SDWIS

Source: EPA SDWIS Federal Reports Search

State Regulator

Pennsylvania Drinking Water Authority

Pennsylvania DEP, Bureau of Safe Drinking Water is the primacy agency that licenses and inspects Warminster Municipal Authority under EPA-delegated authority.

Open PA regulator portal

Source: Pennsylvania DEP, Bureau of Safe Drinking Water

Violation Timeline

Each row links to the EPA SDWIS public record for verification. Cross-reference the contaminant code on EPA's federal report to see violation dates, return-to-compliance status, and enforcement actions.

Year (latest) Contaminant Category Count EPA Record
2024 Lead and Copper Rule MR 8 SDWIS / PA1090069 / 5000
2018 Surface Water Treatment Rule MR 12 SDWIS / PA1090069 / 0200
2018 Revised Total Coliform Rule RPT 4 SDWIS / PA1090069 / 8000
2016 Chlorine MR 4 SDWIS / PA1090069 / 0999
2007 Xylenes, Total MR 62 SDWIS / PA1090069 / 2955
2007 p-Dichlorobenzene MR 62 SDWIS / PA1090069 / 2969
2007 1,1-Dichloroethylene MR 62 SDWIS / PA1090069 / 2977
2007 1,2-Dichloroethane MR 62 SDWIS / PA1090069 / 2980
2007 Carbon tetrachloride MR 62 SDWIS / PA1090069 / 2982
2007 Benzene MR 62 SDWIS / PA1090069 / 2990
2007 1,2,4-Trichlorobenzene MR 61 SDWIS / PA1090069 / 2378
2007 o-Dichlorobenzene MR 61 SDWIS / PA1090069 / 2968
2007 1,1,1-Trichloroethane MR 61 SDWIS / PA1090069 / 2981
2007 1,2-Dichloropropane MR 61 SDWIS / PA1090069 / 2983
2007 CHLOROBENZENE MR 61 SDWIS / PA1090069 / 2989

How Warminster Municipal Authority Compares

Cross-reference this system's record against state averages and the federal MCL framework for context.

Metric Warminster Municipal Authority Pennsylvania avg Federal benchmark
Total violations 2,250 150.6 SDWA compliance, any non-zero count is a recorded breach
Health-based violations 1 8.9 Indicates a contaminant exceeded a federal MCL
PFAS detection 2 compounds 57.6% EPA final rule (2024): PFOA/PFOS MCL = 4.0 ppt
Population served 40,000 1,640 Sizing context for compliance burden

Sources: EPA SDWIS and EPA National Primary Drinking Water Regulations (40 CFR Part 141). State averages computed across 7,701 regulated public water systems in Pennsylvania.

Federal MCL reference, Safe Drinking Water Act thresholds
Contaminant Federal MCL / Action Level Note
Lead 0 mg/L (Action Level: 0.015 mg/L) Lead and Copper Rule treatment technique
Arsenic 0.010 mg/L (10 ppb) Health-based MCL since 2006
Total Coliform Treatment technique (RTCR) Indicator organism, monitoring trigger
PFOA / PFOS (PFAS) 4.0 ppt each (final 2024 rule) Compliance deadline 2029 (EPA proposed extending to 2031, not yet final as of May 2026)
Nitrate (as N) 10 mg/L Acute health risk for infants

Frequently Asked Questions

Is Warminster Municipal Authority water safe to drink?
Warminster Municipal Authority (PWS ID: PA1090069) has 2250 recorded violations in the EPA SDWIS database. PFAS contamination has been detected in UCMR5 testing, with 2 PFAS compounds found. This system serves 40,000 people using Surface Water sources.
How many people does Warminster Municipal Authority serve?
Warminster Municipal Authority serves 40,000 people in Warminster, Pennsylvania. It is a Local-owned system using Surface Water water sources with 10,369 service connections.
What type of violations does Warminster Municipal Authority have?
Warminster Municipal Authority has 2,250 total violations: 1 health-based violations (MCL exceedances or treatment failures), 2,219 monitoring/reporting violations, and 0 treatment technique violations. Health-based violations indicate contaminant levels exceeded EPA safe limits.
Has PFAS been detected in Warminster Municipal Authority water?
Yes. UCMR5 testing detected 2 PFAS compounds in Warminster Municipal Authority's water supply: PFBA, PFPeA. PFAS are persistent "forever chemicals" that do not break down in the environment.
What water source does Warminster Municipal Authority use?
Warminster Municipal Authority uses Surface Water as its primary water source. It is classified as a Community Water System (CWS), serving residential populations year-round.
Where does this data come from?
All data comes from the EPA Safe Drinking Water Information System (SDWIS) and the UCMR5 PFAS monitoring program. SDWIS tracks compliance for all public water systems regulated under the Safe Drinking Water Act.
Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. PFAS data from EPA UCMR5 monitoring program (2023-2025). This data is provided for informational purposes only.
Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater Editorial

Every figure on PlainWater is rendered directly from EPA SDWIS drinking-water data, no number is typed in by an editor. This system's figures are rendered directly from EPA SDWIS data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.