PlainWater

Community Water System · PWS KY0490096

Cynthiana Municipal Water Works

Cynthiana, Kentucky 41031 - drinking water served from surface water sources to 7,263 people, tracked in EPA SDWIS and UCMR5.

7,263
People served
754
EPA violations
86
Health-based
5 PFAS
UCMR5 result

The verdict

EPA records 754 drinking-water violations at Cynthiana Municipal Water Works, 11% of them health-based - above the Kentucky per-system average, and UCMR5 testing detected 5 PFAS compounds.

754
Total EPA violations on record
11%
Health-based (MCL / treatment failure)
7,263
People served by this system
5
PFAS compounds detected (UCMR5)

Water Quality Snapshot: Cynthiana Municipal Water Works

Cynthiana Municipal Water Works is a local-owned community water system that delivers drinking water to 7,263 residents in Cynthiana, Kentucky (Harrison County) through 2,653 service connections. Its water is drawn from surface water sources. EPA's Safe Drinking Water Information System records 754 total violations for this system , of which 86 (11%) are health-based, meaning a contaminant exceeded an EPA Maximum Contaminant Level or a required treatment technique failed. A further 660 monitoring and reporting violations are on file. The most recent violation on record dates to 2015.

The most frequently cited contaminant at this system is Total Haloacetic Acids (HAA5), recorded in 45 violations (MCL, health-based). Under EPA's UCMR5 PFAS monitoring program, 5 PFAS compounds were detected in samples collected from this system, with a maximum reported concentration of 37 ppt (parts per trillion). PFAS are persistent synthetic chemicals linked to health effects at very low exposure levels.

Across Kentucky, EPA tracks 424 public water systems serving 4,570,541 people, with 80,482 cumulative violations and 12,554 health-based violations on record. About 99% of systems in the state carry at least one violation, and state-wide the average per system is 189.8 violations. Statewide, 107 of 231 UCMR5-tested systems have reported PFAS detections (46.3%).

Cynthiana Municipal Water Works's 754 violations sit above the Kentucky average.

All figures above are sourced directly from EPA SDWIS and UCMR5 public data releases and are updated as EPA publishes new reporting cycles.

PFAS Detected

5 PFAS "forever chemicals" detected in testing under EPA's UCMR5 monitoring program.

Population Served
7,263
Total Violations
754
Health-Based Violations
86
Water Source
Surface Water

System Details

System Type
Community
Owner Type
Local
Connections
2,653
County
Harrison
School/Daycare
No
MCL Violations
58
Monitoring Violations
660
Treatment Tech Violations
28

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Total Haloacetic Acids (HAA5) MCL 45 2006
Trichloroethylene MR 23 2009
Tetrachloroethylene MR 23 2009
o-Dichlorobenzene MR 17 2009
CARBON, TOTAL TT 16 2009
Total Haloacetic Acids (HAA5) MR 16 2010
Hexachlorocyclopentadiene MR 15 1999
1,2,4-Trichlorobenzene MR 15 2009
cis-1,2-Dichloroethylene MR 15 2009
Xylenes, Total MR 15 2009
p-Dichlorobenzene MR 15 2009
1,1-Dichloroethylene MR 15 2009
1,1,1-Trichloroethane MR 15 2009
Carbon tetrachloride MR 15 2009
1,1,2-Trichloroethane MR 15 2009
CHLOROBENZENE MR 15 2009
Benzene MR 15 2009
Toluene MR 15 2009
Ethylbenzene MR 15 2009
Styrene MR 15 2009
1,2-Dichloroethane MR 15 2009
1,2-Dichloropropane MR 15 2009
DICHLOROMETHANE MR 15 2009
trans-1,2-Dichloroethylene MR 15 2009
Vinyl chloride MR 15 2009
2,4-D MR 13 2002
Surface Water Treatment Rule TT 12 2006
TTHM MR 8 2006
Coliform (TCR) MCL 8 2014
Nitrate MR 8 2012

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 8 of 116 samples detected PFAS.

Contaminant Date Result MRL Status
PFOA 7/9/2024 <4.00 ppt 4.00 ppt Not Detected
PFDA 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxA 7/9/2024 5.80 ppt 3.00 ppt Detected
PFUnA 7/9/2024 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 7/9/2024 <5.00 ppt 5.00 ppt Not Detected
9Cl-PF3ONS 7/9/2024 <2.00 ppt 2.00 ppt Not Detected
ADONA 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
HFPO-DA 7/9/2024 <5.00 ppt 5.00 ppt Not Detected
PFBA 7/9/2024 <5.00 ppt 5.00 ppt Not Detected
6:2 FTS 7/9/2024 <5.00 ppt 5.00 ppt Not Detected
PFNA 7/9/2024 <4.00 ppt 4.00 ppt Not Detected
PFPeS 7/9/2024 <4.00 ppt 4.00 ppt Not Detected
PFHxS 7/9/2024 11.00 ppt 3.00 ppt Detected
PFHpS 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
8:2 FTS 7/9/2024 <5.00 ppt 5.00 ppt Not Detected
PFMPA 7/9/2024 <4.00 ppt 4.00 ppt Not Detected
PFPeA 7/9/2024 7.10 ppt 3.00 ppt Detected
PFMBA 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
PFEESA 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
NFDHA 7/9/2024 <20.00 ppt 20.00 ppt Not Detected
PFHpA 7/9/2024 3.10 ppt 3.00 ppt Detected
PFBS 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
4:2 FTS 7/9/2024 <3.00 ppt 3.00 ppt Not Detected
NMeFOSAA 7/9/2024 <6.00 ppt 6.00 ppt Not Detected
NEtFOSAA 7/9/2024 <5.00 ppt 5.00 ppt Not Detected
PFTrDA 7/9/2024 <7.00 ppt 7.00 ppt Not Detected
PFTA 7/9/2024 <8.00 ppt 8.00 ppt Not Detected
PFOS 7/9/2024 37.00 ppt 4.00 ppt Detected
PFHxA 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFDA 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFOA 4/16/2024 <4.00 ppt 4.00 ppt Not Detected
PFOS 4/16/2024 <4.00 ppt 4.00 ppt Not Detected
PFNA 4/16/2024 <4.00 ppt 4.00 ppt Not Detected
PFHxS 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFHpA 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
4:2 FTS 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
NEtFOSAA 4/16/2024 <5.00 ppt 5.00 ppt Not Detected
PFBS 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFMPA 4/16/2024 <4.00 ppt 4.00 ppt Not Detected
PFHpS 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeS 4/16/2024 <4.00 ppt 4.00 ppt Not Detected
NFDHA 4/16/2024 <20.00 ppt 20.00 ppt Not Detected
PFEESA 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFBA 4/16/2024 <5.00 ppt 5.00 ppt Not Detected
PFPeA 4/16/2024 <3.00 ppt 3.00 ppt Not Detected
PFUnA 4/16/2024 <2.00 ppt 2.00 ppt Not Detected
8:2 FTS 4/16/2024 <5.00 ppt 5.00 ppt Not Detected
6:2 FTS 4/16/2024 <5.00 ppt 5.00 ppt Not Detected

Verify This Water System

The figures above are aggregated from EPA's public databases. To verify the underlying records, or to file a complaint, request a Consumer Confidence Report, or check current monitoring status, go directly to the federal and state regulators that enforce the Safe Drinking Water Act for Cynthiana Municipal Water Works.

Federal Source of Truth

EPA SDWIS, Federal Reports

EPA's Safe Drinking Water Information System (SDWIS) holds the federal compliance record for every regulated public water system. Open the system-level report by PWS ID:

View PWS ID KY0490096 on SDWIS

Source: EPA SDWIS Federal Reports Search

State Regulator

Kentucky Drinking Water Authority

Kentucky's primacy agency administers the Safe Drinking Water Act locally. Search EPA SDWIS for the current state contact, or use the state's public health or environment department portal.

Find KY regulator via EPA SDWIS

Violation Timeline

Each row links to the EPA SDWIS public record for verification. Cross-reference the contaminant code on EPA's federal report to see violation dates, return-to-compliance status, and enforcement actions.

Year (latest) Contaminant Category Count EPA Record
2015 Public Notice Other 2 SDWIS / KY0490096 / 7500
2014 Coliform (TCR) MCL 8 SDWIS / KY0490096 / 3100
2014 Surface Water Treatment Rule MR 7 SDWIS / KY0490096 / 0200
2012 Nitrate MR 8 SDWIS / KY0490096 / 1040
2010 Total Haloacetic Acids (HAA5) MR 16 SDWIS / KY0490096 / 2456
2009 Trichloroethylene MR 23 SDWIS / KY0490096 / 2984
2009 Tetrachloroethylene MR 23 SDWIS / KY0490096 / 2987
2009 o-Dichlorobenzene MR 17 SDWIS / KY0490096 / 2968
2009 CARBON, TOTAL TT 16 SDWIS / KY0490096 / 2920
2009 1,2,4-Trichlorobenzene MR 15 SDWIS / KY0490096 / 2378
2009 cis-1,2-Dichloroethylene MR 15 SDWIS / KY0490096 / 2380
2009 Xylenes, Total MR 15 SDWIS / KY0490096 / 2955
2009 p-Dichlorobenzene MR 15 SDWIS / KY0490096 / 2969
2009 1,1-Dichloroethylene MR 15 SDWIS / KY0490096 / 2977
2009 1,1,1-Trichloroethane MR 15 SDWIS / KY0490096 / 2981

How Cynthiana Municipal Water Works Compares

Cross-reference this system's record against state averages and the federal MCL framework for context.

Metric Cynthiana Municipal Water Works Kentucky avg Federal benchmark
Total violations 754 189.8 SDWA compliance, any non-zero count is a recorded breach
Health-based violations 86 29.6 Indicates a contaminant exceeded a federal MCL
PFAS detection 5 compounds 46.3% EPA final rule (2024): PFOA/PFOS MCL = 4.0 ppt
Population served 7,263 10,780 Sizing context for compliance burden

Sources: EPA SDWIS and EPA National Primary Drinking Water Regulations (40 CFR Part 141). State averages computed across 424 regulated public water systems in Kentucky.

Federal MCL reference, Safe Drinking Water Act thresholds
Contaminant Federal MCL / Action Level Note
Lead 0 mg/L (Action Level: 0.015 mg/L) Lead and Copper Rule treatment technique
Arsenic 0.010 mg/L (10 ppb) Health-based MCL since 2006
Total Coliform Treatment technique (RTCR) Indicator organism, monitoring trigger
PFOA / PFOS (PFAS) 4.0 ppt each (final 2024 rule) Compliance deadline 2029 (EPA proposed extending to 2031, not yet final as of May 2026)
Nitrate (as N) 10 mg/L Acute health risk for infants

Frequently Asked Questions

Is Cynthiana Municipal Water Works water safe to drink?
Cynthiana Municipal Water Works (PWS ID: KY0490096) has 754 recorded violations in the EPA SDWIS database. PFAS contamination has been detected in UCMR5 testing, with 5 PFAS compounds found. This system serves 7,263 people using Surface Water sources.
How many people does Cynthiana Municipal Water Works serve?
Cynthiana Municipal Water Works serves 7,263 people in Cynthiana, Kentucky. It is a Local-owned system using Surface Water water sources with 2,653 service connections.
What type of violations does Cynthiana Municipal Water Works have?
Cynthiana Municipal Water Works has 754 total violations: 86 health-based violations (MCL exceedances or treatment failures), 660 monitoring/reporting violations, and 28 treatment technique violations. Health-based violations indicate contaminant levels exceeded EPA safe limits.
Has PFAS been detected in Cynthiana Municipal Water Works water?
Yes. UCMR5 testing detected 5 PFAS compounds in Cynthiana Municipal Water Works's water supply: PFHxA, PFHxS, PFPeA, PFHpA, PFOS. PFAS are persistent "forever chemicals" that do not break down in the environment.
What water source does Cynthiana Municipal Water Works use?
Cynthiana Municipal Water Works uses Surface Water as its primary water source. It is classified as a Community Water System (CWS), serving residential populations year-round.
Where does this data come from?
All data comes from the EPA Safe Drinking Water Information System (SDWIS) and the UCMR5 PFAS monitoring program. SDWIS tracks compliance for all public water systems regulated under the Safe Drinking Water Act.
Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. PFAS data from EPA UCMR5 monitoring program (2023-2025). This data is provided for informational purposes only.
Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater Editorial

Every figure on PlainWater is rendered directly from EPA SDWIS drinking-water data, no number is typed in by an editor. This system's figures are rendered directly from EPA SDWIS data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.