PlainWater

Non-Transient Non-Community Water System · PWS WY5600919

Exxon Mobil - Shute Creek Gas Plant

Operator location Kemmerer, Wyoming - 67% of 110 violations are health-based (upper-third health share (> 23%)); surface water source; 250 served per SDWIS.

250
People served (this PWS)
110
EPA violations (this PWS)
74
Health-based (this PWS)
Untested
UCMR5 (this PWS)
Follow published updates (RSS)

Exxon Mobil - Shute Creek Gas Plant standing, high SDWIS violation third

67% of 110 recorded violations are health-based - upper-third health share (> 23%). Corpus terciles use 29,740 systems serving 500+ (the sitemap cohort). Health-based share 67% is upper-third health share (> 23%).

The verdict

Exxon Mobil - Shute Creek Gas Plant sits in the upper third of the sitemap cohort by violation count (110), so the tables below sample a dense compliance trail rather than a near-clean ledger. Population served is smaller (250; smaller served population (≤ 999)), so each violation row represents a compact service footprint. Health-based share is 67% - most of this ledger is MCL or treatment-technique exceedance. No UCMR5 PFAS test appears for this system in this extract.

110
Total EPA violations on record
67%
Health-based (MCL / treatment failure)
250
People served by this PWS (SDWIS)
N/A
PFAS compounds detected (UCMR5)

Population ordinals match the sitemap cohort (systems serving 500+, population_served DESC). See methodology · corpus placement.

System Details

System Type
Non-Transient Non-Community
Owner Type
Private
Connections
10
County
Lincoln
School/Daycare
No
MCL Violations
46
Monitoring Violations
32
Treatment Tech Violations
28

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Total Haloacetic Acids (HAA5) MCL 29 2025
Surface Water Treatment Rule TT 20 2024
Surface Water Treatment Rule MR 17 2024
TTHM MCL 17 2025
Interim Enhanced Surface Water Treatment Rule TT 8 2023
Coliform (TCR) MR 4 1996
Total Haloacetic Acids (HAA5) MR 3 2024
TTHM MR 3 2024
CYANIDE MR 1 1997
Beryllium, Total MR 1 1997
Thallium, Total MR 1 1997
Antimony, Total MR 1 1997
Nickel MR 1 1997

Violation Count vs. the National Corpus

Exxon Mobil - Shute Creek Gas Plant has 110 recorded EPA violations, 75% of the 29,740 public water systems serving 500+ people nationwide carry fewer, and 25% carry more. 67% of this system's own violations are health-based (74 of 110), and it ranks unranked by population served among that same cohort.

EPA violations vs. the national water-system corpus

Public water systems serving 500+ people (EPA SDWIS)

110 Around the middle fewer violations than 25% of 29,740 water systems

the national water-system corpus, bucketed by value

Each bar is a band; taller bars hold more water systems. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source EPA SDWIS · 2026-05-15

Health-based violations on Exxon Mobil - Shute Creek Gas Plant

74 health-based rows in the tables above map to MCL or treatment-technique exceedances, verify each contaminant code on the federal SDWIS report for WY5600919.

Sources: EPA SDWIS

Nationwide peers

110 violations · 250 served: nearest cross-state SDWIS matches.

Cross-state systems with comparable violation load

Nearest cross-state community systems (500+ served) by total SDWIS violations on record.

4 peers

What to do with Exxon Mobil - Shute Creek Gas Plant

Use this system's EPA-reported record as a starting filter, not a final verdict.

  • See how every tracked system in Wyoming compares on the same EPA violation measures. Wyoming systems
  • Check whether PFAS was detected at this system under UCMR5 testing. PFAS guide
  • Find and compare another public water system by name or PWSID. Search systems

EPA SDWIS and UCMR5 figures are informational only, not a substitute for a certified lab test of your own tap water.

Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater