PlainWater

Community Water System · PWS VA3053210

Azzie Manor Home for Adults

Operator location Dewitt, Virginia - smaller served population (≤ 999) at 39 people served; 466 SDWIS violations on record from groundwater sources.

39
People served (this PWS)
466
EPA violations (this PWS)
93
Health-based (this PWS)
Untested
UCMR5 (this PWS)
Follow published updates (RSS)

Azzie Manor Home for Adults standing, high SDWIS violation third

39 people served (SDWIS) - smaller served population (≤ 999). Corpus terciles use 29,740 systems serving 500+ (the sitemap cohort). Health-based share 20% is middle-third health share (≤ 23%).

The verdict

Azzie Manor Home for Adults sits in the upper third of the sitemap cohort by violation count (466), so the tables below sample a dense compliance trail rather than a near-clean ledger. Population served is smaller (39; smaller served population (≤ 999)), so each violation row represents a compact service footprint. Health-based share is 20% (middle-third health share (≤ 23%)). No UCMR5 PFAS test appears for this system in this extract.

466
Total EPA violations on record
20%
Health-based (MCL / treatment failure)
39
People served by this PWS (SDWIS)
N/A
PFAS compounds detected (UCMR5)

Population ordinals match the sitemap cohort (systems serving 500+, population_served DESC). See methodology · corpus placement.

System Details

System Type
Community
Owner Type
Private
Connections
1
County
Dinwiddie
School/Daycare
No
MCL Violations
87
Monitoring Violations
357
Treatment Tech Violations
6

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Coliform (TCR) MR 172 2016
E. COLI MR 44 2018
Combined Uranium MCL 31 2022
Coliform (TCR) MCL 30 2015
Revised Total Coliform Rule MON 30 2021
Gross Alpha, Excl. Radon and U MCL 26 2021
Lead and Copper Rule MR 21 2020
Public Notice Other 10 2015
1,2,4-Trichlorobenzene MR 4 2011
cis-1,2-Dichloroethylene MR 4 2011
DICHLOROMETHANE MR 4 2011
o-Dichlorobenzene MR 4 2011
p-Dichlorobenzene MR 4 2011
1,1-Dichloroethylene MR 4 2011
1,2-Dichloroethane MR 4 2011
1,1,1-Trichloroethane MR 4 2011
Carbon tetrachloride MR 4 2011
Trichloroethylene MR 4 2011
CHLOROBENZENE MR 4 2011
Toluene MR 4 2011
Ethylbenzene MR 4 2011
Styrene MR 4 2011
Revised Total Coliform Rule TT 4 2016
Revised Total Coliform Rule RPT 4 2016
Vinyl chloride MR 4 2011
Benzene MR 4 2011
trans-1,2-Dichloroethylene MR 4 2011
1,1,2-Trichloroethane MR 4 2011
Tetrachloroethylene MR 4 2011
Xylenes, Total MR 4 2011

Violation Count vs. the National Corpus

Azzie Manor Home for Adults has 466 recorded EPA violations, 95% of the 29,740 public water systems serving 500+ people nationwide carry fewer, and 5% carry more. 20% of this system's own violations are health-based (93 of 466), and it ranks unranked by population served among that same cohort.

EPA violations vs. the national water-system corpus

Public water systems serving 500+ people (EPA SDWIS)

466 Higher than most more violations than 95% of 29,740 water systems

the national water-system corpus, bucketed by value

Each bar is a band; taller bars hold more water systems. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source EPA SDWIS · 2026-05-15

Population served record for Azzie Manor Home for Adults

EPA SDWIS lists 39 people served and 1 connections for this PWS, confirm the service-area footprint on the federal report before comparing to municipal census totals.

Sources: EPA SDWIS · Virginia Department of Health, Office of Drinking Water

Nationwide peers

466 violations · 39 served: nearest cross-state SDWIS matches.

Cross-state systems with comparable violation load

Nearest cross-state community systems (500+ served) by total SDWIS violations on record.

4 peers

What to do with Azzie Manor Home for Adults

Use this system's EPA-reported record as a starting filter, not a final verdict.

  • See how every tracked system in Virginia compares on the same EPA violation measures. Virginia systems
  • Check whether PFAS was detected at this system under UCMR5 testing. PFAS guide
  • Find and compare another public water system by name or PWSID. Search systems

EPA SDWIS and UCMR5 figures are informational only, not a substitute for a certified lab test of your own tap water.

Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater