PlainWater

LOUETTA NORTH PUD

PWS ID: TX1011870 · HOUSTON, Texas 77057-1762

LOUETTA NORTH PUD serves 4,836 people in HOUSTON, Texas using Surface Water water sources. It has 5 recorded EPA violations, including 0 health-based violations. PFAS "forever chemicals" were detected in UCMR5 testing (3 compounds found).

Water Quality Snapshot: LOUETTA NORTH PUD

LOUETTA NORTH PUD is a local-owned community water system that delivers drinking water to 4,836 residents in HOUSTON, Texas (Harris County) through 1,659 service connections. Its water is drawn from surface water sources. EPA's Safe Drinking Water Information System records 5 total violations for this system , of which 0 (0%) are health-based — meaning a contaminant exceeded an EPA Maximum Contaminant Level or a required treatment technique failed.

No specific contaminant violations have been recorded in EPA's detailed violation register for this system. Under EPA's UCMR5 PFAS monitoring program, 3 PFAS compounds were detected in samples collected from this system, with a maximum reported concentration of 0.0085 ppt. PFAS are persistent synthetic chemicals linked to health effects at very low exposure levels.

Across Texas, EPA tracks 7,351 public water systems serving 33,253,313 people, with 746,210 cumulative violations and 162,945 health-based violations on record. About 90% of systems in the state carry at least one violation, and state-wide the average per system is 101.5 violations. LOUETTA NORTH PUD's 5 violations sit below the Texas average. Statewide, 1,068 of 1,147 UCMR5-tested systems have reported PFAS detections (93.1%). All figures above are sourced directly from EPA SDWIS and UCMR5 public data releases and are updated as EPA publishes new reporting cycles.

PFAS Detected

3 PFAS "forever chemicals" detected in testing under EPA's UCMR5 monitoring program.

Population Served
4,836
Total Violations
5
Health-Based Violations
0
Water Source
Surface Water

System Details

System Type
Community
Owner Type
Local
Connections
1,659
County
Harris
School/Daycare
No
MCL Violations
0
Monitoring Violations
0
Treatment Tech Violations
0

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 4 of 120 samples detected PFAS.

Contaminant Date Result MRL Status
lithium 9/26/2023 <9 µg/L 9 µg/L Not Detected
9Cl-PF3ONS 8/14/2024 <0.002 µg/L 0.002 µg/L Not Detected
PFHpA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFHxS 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFNA 8/14/2024 <0.004 µg/L 0.004 µg/L Not Detected
PFOS 8/14/2024 <0.004 µg/L 0.004 µg/L Not Detected
PFOA 8/14/2024 <0.004 µg/L 0.004 µg/L Not Detected
PFEESA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
NFDHA 8/14/2024 <0.02 µg/L 0.02 µg/L Not Detected
PFPeS 8/14/2024 <0.004 µg/L 0.004 µg/L Not Detected
PFHpS 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFDA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFDoA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFBS 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFUnA 8/14/2024 <0.002 µg/L 0.002 µg/L Not Detected
11Cl-PF3OUdS 8/14/2024 <0.005 µg/L 0.005 µg/L Not Detected
HFPO-DA 8/14/2024 <0.005 µg/L 0.005 µg/L Not Detected
PFBA 8/14/2024 0.0054 µg/L 0.005 µg/L Detected
6:2 FTS 8/14/2024 <0.005 µg/L 0.005 µg/L Not Detected
4:2 FTS 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
8:2 FTS 8/14/2024 <0.005 µg/L 0.005 µg/L Not Detected
PFMPA 8/14/2024 <0.004 µg/L 0.004 µg/L Not Detected
PFPeA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFMBA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
PFHxA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
ADONA 8/14/2024 <0.003 µg/L 0.003 µg/L Not Detected
11Cl-PF3OUdS 6/21/2023 <0.005 µg/L 0.005 µg/L Not Detected
9Cl-PF3ONS 6/21/2023 <0.002 µg/L 0.002 µg/L Not Detected
ADONA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
HFPO-DA 6/21/2023 <0.005 µg/L 0.005 µg/L Not Detected
PFUnA 6/21/2023 <0.002 µg/L 0.002 µg/L Not Detected
PFBA 6/21/2023 <0.005 µg/L 0.005 µg/L Not Detected
6:2 FTS 6/21/2023 <0.005 µg/L 0.005 µg/L Not Detected
8:2 FTS 6/21/2023 <0.005 µg/L 0.005 µg/L Not Detected
PFPeA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
PFHxA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
PFTrDA 6/21/2023 <0.007 µg/L 0.007 µg/L Not Detected
PFEESA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
NEtFOSAA 6/21/2023 <0.005 µg/L 0.005 µg/L Not Detected
PFTA 6/21/2023 <0.008 µg/L 0.008 µg/L Not Detected
PFDoA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
PFDA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
PFOA 6/21/2023 <0.004 µg/L 0.004 µg/L Not Detected
PFOS 6/21/2023 <0.004 µg/L 0.004 µg/L Not Detected
PFNA 6/21/2023 <0.004 µg/L 0.004 µg/L Not Detected
PFHpS 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
NFDHA 6/21/2023 <0.02 µg/L 0.02 µg/L Not Detected
PFMBA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
PFHxS 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected
PFHpA 6/21/2023 <0.003 µg/L 0.003 µg/L Not Detected

Verify This Water System

The figures above are aggregated from EPA's public databases. To verify the underlying records — or to file a complaint, request a Consumer Confidence Report, or check current monitoring status — go directly to the federal and state regulators that enforce the Safe Drinking Water Act for LOUETTA NORTH PUD.

Federal Source of Truth

EPA SDWIS — Federal Reports

EPA's Safe Drinking Water Information System (SDWIS) holds the federal compliance record for every regulated public water system. Open the system-level report by PWS ID:

View PWS ID TX1011870 on SDWIS

Source: EPA SDWIS Federal Reports Search

State Regulator

Texas Drinking Water Authority

Texas Commission on Environmental Quality (TCEQ) — Drinking Water Watch is the primacy agency that licenses and inspects LOUETTA NORTH PUD under EPA-delegated authority.

Open TX regulator portal

Source: Texas Commission on Environmental Quality (TCEQ) — Drinking Water Watch

How LOUETTA NORTH PUD Compares

Cross-reference this system's record against state averages and the federal MCL framework for context.

Metric LOUETTA NORTH PUD Texas avg Federal benchmark
Total violations 5 101.5 SDWA compliance — any non-zero count is a recorded breach
Health-based violations 0 22.2 Indicates a contaminant exceeded a federal MCL
PFAS detection 3 compounds 93.1% EPA final rule (2024): PFOA/PFOS MCL = 4.0 ppt
Population served 4,836 4,524 Sizing context for compliance burden

Sources: EPA SDWIS and EPA National Primary Drinking Water Regulations (40 CFR Part 141). State averages computed across 7,351 regulated public water systems in Texas.

Federal MCL reference — Safe Drinking Water Act thresholds
Contaminant Federal MCL / Action Level Note
Lead 0 mg/L (Action Level: 0.015 mg/L) Lead and Copper Rule treatment technique
Arsenic 0.010 mg/L (10 ppb) Health-based MCL since 2006
Total Coliform Treatment technique (RTCR) Indicator organism, monitoring trigger
PFOA / PFOS (PFAS) 4.0 ppt each (final 2024 rule) Compliance deadline 2029
Nitrate (as N) 10 mg/L Acute health risk for infants

Frequently Asked Questions

Is LOUETTA NORTH PUD water safe to drink?
LOUETTA NORTH PUD (PWS ID: TX1011870) has 5 recorded violations in the EPA SDWIS database. PFAS contamination has been detected in UCMR5 testing, with 3 PFAS compounds found. This system serves 4,836 people using Surface Water sources.
How many people does LOUETTA NORTH PUD serve?
LOUETTA NORTH PUD serves 4,836 people in HOUSTON, Texas. It is a Local-owned system using Surface Water water sources with 1,659 service connections.
What type of violations does LOUETTA NORTH PUD have?
LOUETTA NORTH PUD has 5 total violations: 0 health-based violations (MCL exceedances or treatment failures), 0 monitoring/reporting violations, and 0 treatment technique violations. Health-based violations indicate contaminant levels exceeded EPA safe limits.
Has PFAS been detected in LOUETTA NORTH PUD water?
Yes. UCMR5 testing detected 3 PFAS compounds in LOUETTA NORTH PUD's water supply: PFBA, PFPeA, PFHxA. PFAS are persistent "forever chemicals" that do not break down in the environment.
What water source does LOUETTA NORTH PUD use?
LOUETTA NORTH PUD uses Surface Water as its primary water source. It is classified as a Community Water System (CWS), serving residential populations year-round.
Where does this data come from?
All data comes from the EPA Safe Drinking Water Information System (SDWIS) and the UCMR5 PFAS monitoring program. SDWIS tracks compliance for all public water systems regulated under the Safe Drinking Water Act.

Explore PlainWater

Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. PFAS data from EPA UCMR5 monitoring program (2023-2025). This data is provided for informational purposes only.

Related

Data sourced from $official public datasets. See our methodology for details. Retrieved and formatted by PlainWater Editorial