PlainWater

Non-Transient Non-Community Water System · PWS PA7220373

Londonderry Elem Sch

Operator location Hummelstown, Pennsylvania - smaller served population (≤ 999) at 465 people served; 373 SDWIS violations on record from groundwater sources.

465
People served (this PWS)
373
EPA violations (this PWS)
15
Health-based (this PWS)
Untested
UCMR5 (this PWS)
Follow published updates (RSS)

Londonderry Elem Sch standing, high SDWIS violation third

465 people served (SDWIS) - smaller served population (≤ 999). Corpus terciles use 29,740 systems serving 500+ (the sitemap cohort). Health-based share 4% is middle-third health share (≤ 23%).

The verdict

Londonderry Elem Sch sits in the upper third of the sitemap cohort by violation count (373), so the tables below sample a dense compliance trail rather than a near-clean ledger. Population served is smaller (465; smaller served population (≤ 999)), so each violation row represents a compact service footprint. Health-based share is 4% (middle-third health share (≤ 23%)). No UCMR5 PFAS test appears for this system in this extract.

373
Total EPA violations on record
4%
Health-based (MCL / treatment failure)
465
People served by this PWS (SDWIS)
N/A
PFAS compounds detected (UCMR5)

Population ordinals match the sitemap cohort (systems serving 500+, population_served DESC). See methodology · corpus placement.

System Details

System Type
Non-Transient Non-Community
Owner Type
Local
Connections
1
County
Dauphin
School/Daycare
Yes
MCL Violations
15
Monitoring Violations
347
Treatment Tech Violations
0

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Nitrite MR 33 2024
Nitrate MR 26 2024
Xylenes, Total MR 15 2001
DICHLOROMETHANE MR 15 2001
o-Dichlorobenzene MR 15 2001
p-Dichlorobenzene MR 15 2001
cis-1,2-Dichloroethylene MR 15 2001
1,2-Dichloroethane MR 13 2001
1,1,1-Trichloroethane MR 13 2001
Carbon tetrachloride MR 13 2001
1,2-Dichloropropane MR 13 2001
1,1,2-Trichloroethane MR 13 2001
Tetrachloroethylene MR 13 2001
CHLOROBENZENE MR 13 2001
Ethylbenzene MR 13 2001
Styrene MR 13 2001
1,2,4-Trichlorobenzene MR 13 2001
1,1-Dichloroethylene MR 13 2001
Benzene MR 13 2001
Toluene MR 13 2001
trans-1,2-Dichloroethylene MR 13 2001
Trichloroethylene MR 13 2001
Lead and Copper Rule MR 10 2016
Benzene MCL 8 2003
Nitrate MCL 7 2006
Revised Total Coliform Rule MON 6 2025
Public Notice Other 4 2006
Coliform (TCR) MR 2 1997

Violation Count vs. the National Corpus

Londonderry Elem Sch has 373 recorded EPA violations, 93% of the 29,740 public water systems serving 500+ people nationwide carry fewer, and 7% carry more. 4% of this system's own violations are health-based (15 of 373), and it ranks unranked by population served among that same cohort.

EPA violations vs. the national water-system corpus

Public water systems serving 500+ people (EPA SDWIS)

373 Higher than most more violations than 93% of 29,740 water systems

the national water-system corpus, bucketed by value

Each bar is a band; taller bars hold more water systems. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source EPA SDWIS · 2026-05-15

Population served record for Londonderry Elem Sch

EPA SDWIS lists 465 people served and 1 connections for this PWS, confirm the service-area footprint on the federal report before comparing to municipal census totals.

Sources: EPA SDWIS · Pennsylvania DEP, Bureau of Safe Drinking Water

Nationwide peers

373 violations · 465 served: nearest cross-state SDWIS matches.

Cross-state systems with comparable violation load

Nearest cross-state community systems (500+ served) by total SDWIS violations on record.

4 peers

What to do with Londonderry Elem Sch

Use this system's EPA-reported record as a starting filter, not a final verdict.

  • See how every tracked system in Pennsylvania compares on the same EPA violation measures. Pennsylvania systems
  • Check whether PFAS was detected at this system under UCMR5 testing. PFAS guide
  • Find and compare another public water system by name or PWSID. Search systems

EPA SDWIS and UCMR5 figures are informational only, not a substitute for a certified lab test of your own tap water.

Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater