PlainWater

CONSOLIDATED RWD #3 CREEK CO

PWS ID: OK3001916 · SAPULPA, Oklahoma 74066

Population Served
3,500
Total Violations
145
Health-Based Violations
36
Water Source
Surface Water

System Details

System Type
Community
Owner Type
Local
Connections
1,400
County
Creek
School/Daycare
No
MCL Violations
35
Monitoring Violations
66
Treatment Tech Violations
1

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Coliform (TCR) MR 39 2012
TTHM MCL 27 2014
Lead and Copper Rule MR 10 2022
Coliform (TCR) MCL 8 2007
TTHM MR 6 2020
Total Haloacetic Acids (HAA5) MR 6 2020
Revised Total Coliform Rule MON 5 2018
Consumer Confidence Rule Other 2 2023
LEAD AND COPPER RULE REVISIONS TT 1 2024
LEAD AND COPPER RULE REVISIONS RPT 1 2024

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 0 of 61 samples detected PFAS.

Contaminant Date Result MRL Status
NEtFOSAA 9/24/2025 <0.005 µg/L 0.005 µg/L Not Detected
NMeFOSAA 9/24/2025 <0.006 µg/L 0.006 µg/L Not Detected
PFTA 9/24/2025 <0.008 µg/L 0.008 µg/L Not Detected
PFTrDA 9/24/2025 <0.007 µg/L 0.007 µg/L Not Detected
PFHpS 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFUnA 8/27/2025 <0.002 µg/L 0.002 µg/L Not Detected
PFPeS 8/27/2025 <0.004 µg/L 0.004 µg/L Not Detected
NFDHA 8/27/2025 <0.02 µg/L 0.02 µg/L Not Detected
PFEESA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFMBA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFPeA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFMPA 8/27/2025 <0.004 µg/L 0.004 µg/L Not Detected
8:2 FTS 8/27/2025 <0.005 µg/L 0.005 µg/L Not Detected
4:2 FTS 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
6:2 FTS 8/27/2025 <0.005 µg/L 0.005 µg/L Not Detected
PFDA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFBS 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFNA 8/27/2025 <0.004 µg/L 0.004 µg/L Not Detected
PFHxS 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFOS 8/27/2025 <0.004 µg/L 0.004 µg/L Not Detected
PFBA 8/27/2025 <0.005 µg/L 0.005 µg/L Not Detected
PFOA 8/27/2025 <0.004 µg/L 0.004 µg/L Not Detected
PFDoA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFHxA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
11Cl-PF3OUdS 8/27/2025 <0.005 µg/L 0.005 µg/L Not Detected
9Cl-PF3ONS 8/27/2025 <0.002 µg/L 0.002 µg/L Not Detected
ADONA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
HFPO-DA 8/27/2025 <0.005 µg/L 0.005 µg/L Not Detected
PFHpA 8/27/2025 <0.003 µg/L 0.003 µg/L Not Detected
lithium 8/21/2025 <9 µg/L 9 µg/L Not Detected
PFHxS 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFHpS 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFPeS 6/5/2025 <0.004 µg/L 0.004 µg/L Not Detected
PFOA 6/5/2025 <0.004 µg/L 0.004 µg/L Not Detected
PFDA 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFEESA 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
9Cl-PF3ONS 6/5/2025 <0.002 µg/L 0.002 µg/L Not Detected
PFPeA 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFMPA 6/5/2025 <0.004 µg/L 0.004 µg/L Not Detected
8:2 FTS 6/5/2025 <0.005 µg/L 0.005 µg/L Not Detected
4:2 FTS 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
6:2 FTS 6/5/2025 <0.005 µg/L 0.005 µg/L Not Detected
PFBA 6/5/2025 <0.005 µg/L 0.005 µg/L Not Detected
PFNA 6/5/2025 <0.004 µg/L 0.004 µg/L Not Detected
ADONA 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFOS 6/5/2025 <0.004 µg/L 0.004 µg/L Not Detected
11Cl-PF3OUdS 6/5/2025 <0.005 µg/L 0.005 µg/L Not Detected
PFUnA 6/5/2025 <0.002 µg/L 0.002 µg/L Not Detected
PFHxA 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
PFDoA 6/5/2025 <0.003 µg/L 0.003 µg/L Not Detected
Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. PFAS data from EPA UCMR5 monitoring program (2023-2025). This data is provided for informational purposes only.