Operator location Dracut, Massachusetts - larger served population (> 3,309) at 25,789 people served; 114 SDWIS violations on record from surface water sources.

25,789
People served (this PWS) Larger third of systems
114
EPA violations (this PWS) Upper third of systems
3
Health-based (this PWS) Middle third by health-based share
3 PFAS
UCMR5 (this PWS) Middle third of PFAS-detected systems
Follow published updates (RSS)

Dracut Water Supply District standing, high SDWIS violation third

25,789 people served (SDWIS) - larger served population (> 3,309). Corpus terciles use 29,740 systems serving 500+ (the sitemap cohort). Health-based share 3% is middle-third health share (≤ 23%). UCMR5: middle-third PFAS panel (≤ 4 compounds). Population rank #2,156 of 29,740 among systems serving 500+.

The verdict

Dracut Water Supply District sits in the upper third of the sitemap cohort by violation count (114), so the tables below sample a dense compliance trail rather than a near-clean ledger. Population served is large (25,789; larger served population (> 3,309)), so household exposure scale sits behind the violation mix. Health-based share is 3% (middle-third health share (≤ 23%)). UCMR5 detected 3 PFAS compounds (middle-third PFAS panel (≤ 4 compounds)).

#2,156 of 29,740
Population · /systems
#95 of 418
Population · MA
114
Total EPA violations on record
3%
Health-based (MCL / treatment failure)

Population ordinals match the sitemap cohort (systems serving 500+, population_served DESC). See methodology · corpus placement.

PFAS Detected

3 PFAS "forever chemicals" detected in testing under EPA's UCMR5 monitoring program.

F
Water Safety Score
37/100
Dracut Water Supply District

Based on EPA SDWIS violation history and UCMR5 PFAS testing only, not water taste, odor, infrastructure age, or contaminants outside the federally tracked set.

Health-based violations D
3
EPA SDWIS health-based violations on record (MCL, MRDL, treatment technique)
Monitoring & reporting violations F
111
Non-health SDWIS violations (monitoring, reporting, and other compliance)
PFAS contamination D
0.0101 µg/L
Highest PFAS compound level detected in UCMR5 testing

System Details

System Type
Community
Owner Type
Local
Connections
7,659
County
Middlesex
School/Daycare
No
MCL Violations
3
Monitoring Violations
98
Treatment Tech Violations
0

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Coliform (TCR) MCL 3 2014
Lead and Copper Rule MR 2 2005
Carbon tetrachloride MR 2 2007
1,2-Dichloroethane MR 2 2007
1,1,1-Trichloroethane MR 2 2007
1,2-Dichloropropane MR 2 2007
Radium-226 MR 2 2007
Styrene MR 2 2007
Tetrachloroethylene MR 2 2007
Toluene MR 2 2007
Xylenes, Total MR 2 2007
DICHLOROMETHANE MR 2 2007
1,1,2-Trichloroethane MR 2 2007
Radium-228 MR 2 2007
1,2,4-Trichlorobenzene MR 2 2007
Coliform (TCR) MR 2 2014
cis-1,2-Dichloroethylene MR 2 2007
Trichloroethylene MR 2 2007
Benzene MR 2 2007
Ethylbenzene MR 2 2007
Gross Alpha, Excl. Radon and U MR 2 1991
trans-1,2-Dichloroethylene MR 2 2007
Vinyl chloride MR 2 2007
CHLOROBENZENE MR 2 2007
o-Dichlorobenzene MR 2 2007
p-Dichlorobenzene MR 2 2007
1,1-Dichloroethylene MR 2 2007
LASSO MR 1 2007
Atrazine MR 1 2007
Carbofuran MR 1 2007

Violation Count vs. the National Corpus

Dracut Water Supply District has 114 recorded EPA violations, 76% of the 29,740 public water systems serving 500+ people nationwide carry fewer, and 24% carry more. 3% of this system's own violations are health-based (3 of 114), and it ranks #2,156 of 29,740 by population served among that same cohort.

EPA violations vs. the national water-system corpus

Public water systems serving 500+ people (EPA SDWIS)

114 Higher than most more violations than 76% of 29,740 water systems

the national water-system corpus, bucketed by value

Each bar is a band; taller bars hold more water systems. The dashed line + filled bar mark this entry. Hover or tap any bar for its full count and share, and where it sits relative to this entry.

Source EPA SDWIS · 2026-05-15

How many violations vs. how serious, among peer systems

Dracut Water Supply District plotted against 29 peer public water systems (500+ people served), by total violation count (x) and the share of those violations that are health-based (y). The crosshair sits at this sample's own median on each axis. A high violation count does not automatically mean a serious record: most monitoring and reporting violations are minor, not health-based.

Violation volume vs. health-based share

30 public water systems (500+ people served), EPA SDWIS current release. 2×2 strategic matrix plotting 30 entities by Total violations (X) and Health-based share (Y), with a crosshair dividing the plot into four quadrants. Frequent and seriousRare but seriousFrequent, mostly paperworkClean record 0200400600 0%20%40%60%80%100% Total violations Health-based share Violation volume vs. health-based share Miccosukee Service Plaza-0, 0%Brazoria - Fort Bend Counties MUD 3-0, 0%Tanglewilde Thompson Place 600-2, 0%Center Water Co-5, 0%Montgomery Co RWD 12-7, 29%Spring Mills Elem School/Hvs-9, 0%Irvin Water District #6-11, 27%Great Bend Industrial Park-14, 0%Nooksack Valley Water Association-16, 31%Glen Park Village-19, 0%Camp Is-Sho-Da-22, 0%Kipling Oaks 1-25, 16%McLouth, City Of-29, 17%Hamilton-33, 0%Pine Valley Plantation-37, 24%Lake Gibson Estates-42, 2%Ticonderoga WD-47, 26%Town of Welaka-54, 0%Township of Blairstown Dpw-61, 0%McIntosh Water & Fire Pro Authority-71, 0%Sunset Ridge Water District-82, 15%South Deerfield Water Supply District-96, 16%Clarkdale Municipal Water System-114, 0%Orange Water Dept-136, 14%Mount Pleasant Water Sys #1-167, 11%Benson Culinary Improvement District-212, 1%Eureka Water Association-273, 0%City of Ballinger-372, 85%Conemaugh Twp Muni Auth-567, 1%Dracut Water Supply District-114, 3%
30 public water systems (500+ people served), EPA SDWIS current release.

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 7 of 232 samples detected PFAS.

Contaminant Date Result MRL Status
PFNA 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFTA 8/7/2024 <8.00 ppt 8.00 ppt Not Detected
11Cl-PF3OUdS 8/7/2024 <5.00 ppt 5.00 ppt Not Detected
PFBS 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
NMeFOSAA 8/7/2024 <6.00 ppt 6.00 ppt Not Detected
PFHxS 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
NEtFOSAA 8/7/2024 <5.00 ppt 5.00 ppt Not Detected
PFOS 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFOA 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFDA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFUnA 8/7/2024 <2.00 ppt 2.00 ppt Not Detected
PFHpA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
NFDHA 8/7/2024 <20.00 ppt 20.00 ppt Not Detected
PFMBA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFBA 8/7/2024 <5.00 ppt 5.00 ppt Not Detected
HFPO-DA 8/7/2024 <5.00 ppt 5.00 ppt Not Detected
ADONA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
9Cl-PF3ONS 8/7/2024 <2.00 ppt 2.00 ppt Not Detected
PFEESA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeS 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
6:2 FTS 8/7/2024 <5.00 ppt 5.00 ppt Not Detected
4:2 FTS 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
8:2 FTS 8/7/2024 <5.00 ppt 5.00 ppt Not Detected
PFMPA 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFPeA 8/7/2024 3.10 ppt 3.00 ppt Detected
PFTrDA 8/7/2024 <7.00 ppt 7.00 ppt Not Detected
PFHpS 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFTA 8/7/2024 <8.00 ppt 8.00 ppt Not Detected
PFHpA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxS 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFNA 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFOS 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
PFOA 8/7/2024 6.10 ppt 4.00 ppt Detected
PFDA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFUnA 8/7/2024 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 8/7/2024 <5.00 ppt 5.00 ppt Not Detected
9Cl-PF3ONS 8/7/2024 <2.00 ppt 2.00 ppt Not Detected
ADONA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
NMeFOSAA 8/7/2024 <6.00 ppt 6.00 ppt Not Detected
PFHpS 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
4:2 FTS 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeS 8/7/2024 <4.00 ppt 4.00 ppt Not Detected
NFDHA 8/7/2024 <20.00 ppt 20.00 ppt Not Detected
PFEESA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFMBA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeA 8/7/2024 <3.00 ppt 3.00 ppt Not Detected

Population served record for Dracut Water Supply District

EPA SDWIS lists 25,789 people served and 7,659 connections for this PWS, confirm the service-area footprint on the federal report before comparing to municipal census totals.

Sources: EPA SDWIS · MassDEP, Drinking Water Program

Nationwide peers

114 violations · 25,789 served: nearest cross-state SDWIS matches.

What to do with Dracut Water Supply District

Use this system's EPA-reported record as a starting filter, not a final verdict.

EPA SDWIS and UCMR5 figures are informational only, not a substitute for a certified lab test of your own tap water.

Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater

Every figure on PlainWater is rendered directly from EPA SDWIS drinking-water data, no number is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.