PlainWater

SOMERSET WEST WATER CORP

PWS ID: ID3140113 · CALDWELL, Idaho 83607

SOMERSET WEST WATER CORP serves 203 people in CALDWELL, Idaho using Groundwater water sources. It has 65 recorded EPA violations, including 8 health-based violations. No PFAS contamination was detected in UCMR5 testing.

Water Quality Snapshot: SOMERSET WEST WATER CORP

SOMERSET WEST WATER CORP is a private-owned community water system that delivers drinking water to 203 residents in CALDWELL, Idaho (Canyon County) through 56 service connections. Its water is drawn from groundwater sources. EPA's Safe Drinking Water Information System records 65 total violations for this system , of which 8 (12%) are health-based — meaning a contaminant exceeded an EPA Maximum Contaminant Level or a required treatment technique failed. A further 56 monitoring and reporting violations are on file. The most recent violation on record dates to 2023.

The most frequently cited contaminant at this system is Coliform (TCR), recorded in 7 violations (MR). This system has not yet been sampled under EPA's UCMR5 PFAS monitoring program, so no PFAS detection data is available here.

Across Idaho, EPA tracks 2,005 public water systems serving 1,743,912 people, with 104,850 cumulative violations and 19,965 health-based violations on record. About 96% of systems in the state carry at least one violation, and state-wide the average per system is 52.3 violations. SOMERSET WEST WATER CORP's 65 violations sit above the Idaho average. Statewide, 40 of 60 UCMR5-tested systems have reported PFAS detections (66.7%). All figures above are sourced directly from EPA SDWIS and UCMR5 public data releases and are updated as EPA publishes new reporting cycles.

Population Served
203
Total Violations
65
Health-Based Violations
8
Water Source
Groundwater

System Details

System Type
Community
Owner Type
Private
Connections
56
County
Canyon
School/Daycare
No
MCL Violations
4
Monitoring Violations
56
Treatment Tech Violations
4

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Coliform (TCR) MR 7 2016
Groundwater Rule TT 4 2013
Coliform (TCR) MCL 4 2016
Lead and Copper Rule MR 2 2023
Heptachlor MR 1 2002
Heptachlor epoxide MR 1 2002
2,4-D MR 1 2002
2,4,5-TP MR 1 2002
HEXACHLOROBENZENE MR 1 2002
1,2-DIBROMO-3-CHLOROPROPANE MR 1 2002
Pentachlorophenol MR 1 2002
Total Polychlorinated Biphenyls (PCB) MR 1 2002
Chlordane MR 1 2002
Benzene MR 1 1993
Carbon tetrachloride MR 1 1993
cis-1,2-Dichloroethylene MR 1 1993
1,2-Dichloroethane MR 1 1993
1,2-Dichloropropane MR 1 1993
o-Dichlorobenzene MR 1 1993
p-Dichlorobenzene MR 1 1993
Ethylbenzene MR 1 1993
CHLOROBENZENE MR 1 1993
Styrene MR 1 1993
1,1,1-Trichloroethane MR 1 1993
Trichloroethylene MR 1 1993
Toluene MR 1 1993
Endrin MR 1 2002
BHC-GAMMA MR 1 2002
Methoxychlor MR 1 2002
Toxaphene MR 1 2002

Verify This Water System

The figures above are aggregated from EPA's public databases. To verify the underlying records — or to file a complaint, request a Consumer Confidence Report, or check current monitoring status — go directly to the federal and state regulators that enforce the Safe Drinking Water Act for SOMERSET WEST WATER CORP.

Federal Source of Truth

EPA SDWIS — Federal Reports

EPA's Safe Drinking Water Information System (SDWIS) holds the federal compliance record for every regulated public water system. Open the system-level report by PWS ID:

View PWS ID ID3140113 on SDWIS

Source: EPA SDWIS Federal Reports Search

State Regulator

Idaho Drinking Water Authority

Idaho's primacy agency administers the Safe Drinking Water Act locally. Search EPA SDWIS for the current state contact, or use the state's public health or environment department portal.

Find ID regulator via EPA SDWIS

Violation Timeline

Each row links to the EPA SDWIS public record for verification. Cross-reference the contaminant code on EPA's federal report to see violation dates, return-to-compliance status, and enforcement actions.

Year (latest) Contaminant Category Count EPA Record
2023 Lead and Copper Rule MR 2 SDWIS / ID3140113 / 5000
2016 Coliform (TCR) MR 7 SDWIS / ID3140113 / 3100
2016 Coliform (TCR) MCL 4 SDWIS / ID3140113 / 3100
2013 Groundwater Rule TT 4 SDWIS / ID3140113 / 0700
2002 Heptachlor MR 1 SDWIS / ID3140113 / 2065
2002 Heptachlor epoxide MR 1 SDWIS / ID3140113 / 2067
2002 2,4-D MR 1 SDWIS / ID3140113 / 2105
2002 2,4,5-TP MR 1 SDWIS / ID3140113 / 2110
2002 HEXACHLOROBENZENE MR 1 SDWIS / ID3140113 / 2274
2002 1,2-DIBROMO-3-CHLOROPROPANE MR 1 SDWIS / ID3140113 / 2931
2002 Pentachlorophenol MR 1 SDWIS / ID3140113 / 2326
2002 Total Polychlorinated Biphenyls (PCB) MR 1 SDWIS / ID3140113 / 2383
2002 Chlordane MR 1 SDWIS / ID3140113 / 2959
2002 Endrin MR 1 SDWIS / ID3140113 / 2005
2002 BHC-GAMMA MR 1 SDWIS / ID3140113 / 2010

How SOMERSET WEST WATER CORP Compares

Cross-reference this system's record against state averages and the federal MCL framework for context.

Metric SOMERSET WEST WATER CORP Idaho avg Federal benchmark
Total violations 65 52.3 SDWA compliance — any non-zero count is a recorded breach
Health-based violations 8 10 Indicates a contaminant exceeded a federal MCL
PFAS detection None 66.7% EPA final rule (2024): PFOA/PFOS MCL = 4.0 ppt
Population served 203 870 Sizing context for compliance burden

Sources: EPA SDWIS and EPA National Primary Drinking Water Regulations (40 CFR Part 141). State averages computed across 2,005 regulated public water systems in Idaho.

Federal MCL reference — Safe Drinking Water Act thresholds
Contaminant Federal MCL / Action Level Note
Lead 0 mg/L (Action Level: 0.015 mg/L) Lead and Copper Rule treatment technique
Arsenic 0.010 mg/L (10 ppb) Health-based MCL since 2006
Total Coliform Treatment technique (RTCR) Indicator organism, monitoring trigger
PFOA / PFOS (PFAS) 4.0 ppt each (final 2024 rule) Compliance deadline 2029
Nitrate (as N) 10 mg/L Acute health risk for infants

Frequently Asked Questions

Is SOMERSET WEST WATER CORP water safe to drink?
SOMERSET WEST WATER CORP (PWS ID: ID3140113) has 65 recorded violations in the EPA SDWIS database. No PFAS contamination was detected in UCMR5 testing. This system serves 203 people using Groundwater sources.
How many people does SOMERSET WEST WATER CORP serve?
SOMERSET WEST WATER CORP serves 203 people in CALDWELL, Idaho. It is a Private-owned system using Groundwater water sources with 56 service connections.
What type of violations does SOMERSET WEST WATER CORP have?
SOMERSET WEST WATER CORP has 65 total violations: 8 health-based violations (MCL exceedances or treatment failures), 56 monitoring/reporting violations, and 4 treatment technique violations. Health-based violations indicate contaminant levels exceeded EPA safe limits.
Has PFAS been detected in SOMERSET WEST WATER CORP water?
No PFAS testing data is available for SOMERSET WEST WATER CORP under the EPA's UCMR5 monitoring program.
What water source does SOMERSET WEST WATER CORP use?
SOMERSET WEST WATER CORP uses Groundwater as its primary water source. It is classified as a Community Water System (CWS), serving residential populations year-round.
Where does this data come from?
All data comes from the EPA Safe Drinking Water Information System (SDWIS) and the UCMR5 PFAS monitoring program. SDWIS tracks compliance for all public water systems regulated under the Safe Drinking Water Act.

Explore PlainWater

Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. This data is provided for informational purposes only.

Related

Data sourced from $official public datasets. See our methodology for details. Retrieved and formatted by Kiznis Studio Editorial