PlainWater

Community Water System · PWS AZ0414082

Usmc Yuma Main System

Yuma, Arizona 85365 - drinking water served from surface water sources to 6,324 people, tracked in EPA SDWIS and UCMR5.

6,324
People served
350
EPA violations
13
Health-based
1 PFAS
UCMR5 result

The verdict

EPA records 350 drinking-water violations at Usmc Yuma Main System, 4% of them health-based - above the Arizona per-system average, and UCMR5 testing detected 1 PFAS compound.

350
Total EPA violations on record
4%
Health-based (MCL / treatment failure)
6,324
People served by this system
1
PFAS compounds detected (UCMR5)

Water Quality Snapshot: Usmc Yuma Main System

Usmc Yuma Main System is a federal-owned community water system that delivers drinking water to 6,324 residents in Yuma, Arizona (Yuma County) through 1,000 service connections. Its water is drawn from surface water sources. EPA's Safe Drinking Water Information System records 350 total violations for this system , of which 13 (4%) are health-based, meaning a contaminant exceeded an EPA Maximum Contaminant Level or a required treatment technique failed. A further 311 monitoring and reporting violations are on file. The most recent violation on record dates to 2025.

The most frequently cited contaminant at this system is Coliform (TCR), recorded in 23 violations (MR). Under EPA's UCMR5 PFAS monitoring program, 1 PFAS compound was detected in samples collected from this system, with a maximum reported concentration of 3.1 ppt (parts per trillion). PFAS are persistent synthetic chemicals linked to health effects at very low exposure levels.

Across Arizona, EPA tracks 1,493 public water systems serving 7,322,166 people, with 228,944 cumulative violations and 15,663 health-based violations on record. About 98% of systems in the state carry at least one violation, and state-wide the average per system is 153.3 violations. Statewide, 145 of 152 UCMR5-tested systems have reported PFAS detections (95.4%).

Usmc Yuma Main System's 350 violations sit above the Arizona average.

All figures above are sourced directly from EPA SDWIS and UCMR5 public data releases and are updated as EPA publishes new reporting cycles.

PFAS Detected

1 PFAS "forever chemicals" detected in testing under EPA's UCMR5 monitoring program.

Population Served
6,324
Total Violations
350
Health-Based Violations
13
Water Source
Surface Water

System Details

System Type
Community
Owner Type
Federal
Connections
1,000
County
Yuma
School/Daycare
No
MCL Violations
5
Monitoring Violations
311
Treatment Tech Violations
8

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Coliform (TCR) MR 23 2015
Chlorine MR 17 2023
Nitrate MR 15 2018
E. COLI MR 14 2019
Cryptosporidium MR 12 2019
Turbidity MR 12 2019
TTHM MR 10 2025
Revised Total Coliform Rule RPT 9 2025
Total Haloacetic Acids (HAA5) MR 8 2023
Interim Enhanced Surface Water Treatment Rule MR 8 2024
Groundwater Rule TT 8 2024
Consumer Confidence Rule Other 7 2015
DICHLOROMETHANE MR 6 2018
o-Dichlorobenzene MR 6 2018
p-Dichlorobenzene MR 6 2018
1,2-Dichloroethane MR 6 2018
Carbon tetrachloride MR 6 2018
1,2-Dichloropropane MR 6 2018
Trichloroethylene MR 6 2018
Tetrachloroethylene MR 6 2018
Benzene MR 6 2018
Styrene MR 6 2018
cis-1,2-Dichloroethylene MR 6 2018
1,1-Dichloroethylene MR 6 2018
trans-1,2-Dichloroethylene MR 6 2018
1,1,1-Trichloroethane MR 6 2018
CHLOROBENZENE MR 6 2018
Toluene MR 6 2018
Ethylbenzene MR 6 2018
1,1,2-Trichloroethane MR 6 2018

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 1 of 116 samples detected PFAS.

Contaminant Date Result MRL Status
PFBS 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
8:2 FTS 8/7/2023 <5.00 ppt 5.00 ppt Not Detected
PFOS 8/7/2023 <4.00 ppt 4.00 ppt Not Detected
PFOA 8/7/2023 <4.00 ppt 4.00 ppt Not Detected
PFDA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFDoA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFHxA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFUnA 8/7/2023 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 8/7/2023 <5.00 ppt 5.00 ppt Not Detected
9Cl-PF3ONS 8/7/2023 <2.00 ppt 2.00 ppt Not Detected
ADONA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
HFPO-DA 8/7/2023 <5.00 ppt 5.00 ppt Not Detected
PFBA 8/7/2023 <5.00 ppt 5.00 ppt Not Detected
4:2 FTS 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFHpS 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFHpA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFHxS 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
NMeFOSAA 8/7/2023 <6.00 ppt 6.00 ppt Not Detected
NEtFOSAA 8/7/2023 <5.00 ppt 5.00 ppt Not Detected
6:2 FTS 8/7/2023 <5.00 ppt 5.00 ppt Not Detected
PFTA 8/7/2023 <8.00 ppt 8.00 ppt Not Detected
PFNA 8/7/2023 <4.00 ppt 4.00 ppt Not Detected
PFPeS 8/7/2023 <4.00 ppt 4.00 ppt Not Detected
NFDHA 8/7/2023 <20.00 ppt 20.00 ppt Not Detected
PFEESA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFMBA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeA 8/7/2023 <3.00 ppt 3.00 ppt Not Detected
PFMPA 8/7/2023 <4.00 ppt 4.00 ppt Not Detected
PFTrDA 8/7/2023 <7.00 ppt 7.00 ppt Not Detected
PFHpA 5/2/2023 <3.00 ppt 3.00 ppt Not Detected
PFBA 5/2/2023 <5.00 ppt 5.00 ppt Not Detected
PFNA 5/2/2023 <4.00 ppt 4.00 ppt Not Detected
NEtFOSAA 5/2/2023 <5.00 ppt 5.00 ppt Not Detected
PFTrDA 5/2/2023 <7.00 ppt 7.00 ppt Not Detected
PFTA 5/2/2023 <8.00 ppt 8.00 ppt Not Detected
PFHpS 5/2/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeS 5/2/2023 <4.00 ppt 4.00 ppt Not Detected
NFDHA 5/2/2023 <20.00 ppt 20.00 ppt Not Detected
PFEESA 5/2/2023 <3.00 ppt 3.00 ppt Not Detected
PFMBA 5/2/2023 <3.00 ppt 3.00 ppt Not Detected
PFPeA 5/2/2023 <3.00 ppt 3.00 ppt Not Detected
PFMPA 5/2/2023 <4.00 ppt 4.00 ppt Not Detected
8:2 FTS 5/2/2023 <5.00 ppt 5.00 ppt Not Detected
6:2 FTS 5/2/2023 <5.00 ppt 5.00 ppt Not Detected
NMeFOSAA 5/2/2023 <6.00 ppt 6.00 ppt Not Detected
HFPO-DA 5/2/2023 <5.00 ppt 5.00 ppt Not Detected
ADONA 5/2/2023 <3.00 ppt 3.00 ppt Not Detected
9Cl-PF3ONS 5/2/2023 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 5/2/2023 <5.00 ppt 5.00 ppt Not Detected
PFUnA 5/2/2023 <2.00 ppt 2.00 ppt Not Detected

Verify This Water System

The figures above are aggregated from EPA's public databases. To verify the underlying records, or to file a complaint, request a Consumer Confidence Report, or check current monitoring status, go directly to the federal and state regulators that enforce the Safe Drinking Water Act for Usmc Yuma Main System.

Federal Source of Truth

EPA SDWIS, Federal Reports

EPA's Safe Drinking Water Information System (SDWIS) holds the federal compliance record for every regulated public water system. Open the system-level report by PWS ID:

View PWS ID AZ0414082 on SDWIS

Source: EPA SDWIS Federal Reports Search

State Regulator

Arizona Drinking Water Authority

Arizona DEQ, Drinking Water Program is the primacy agency that licenses and inspects Usmc Yuma Main System under EPA-delegated authority.

Open AZ regulator portal

Source: Arizona DEQ, Drinking Water Program

Violation Timeline

Each row links to the EPA SDWIS public record for verification. Cross-reference the contaminant code on EPA's federal report to see violation dates, return-to-compliance status, and enforcement actions.

Year (latest) Contaminant Category Count EPA Record
2025 TTHM MR 10 SDWIS / AZ0414082 / 2950
2025 Revised Total Coliform Rule RPT 9 SDWIS / AZ0414082 / 8000
2024 Interim Enhanced Surface Water Treatment Rule MR 8 SDWIS / AZ0414082 / 0300
2024 Groundwater Rule TT 8 SDWIS / AZ0414082 / 0700
2023 Chlorine MR 17 SDWIS / AZ0414082 / 0999
2023 Total Haloacetic Acids (HAA5) MR 8 SDWIS / AZ0414082 / 2456
2022 CARBON, TOTAL MR 2 SDWIS / AZ0414082 / 2920
2020 Public Notice Other 2 SDWIS / AZ0414082 / 7500
2019 E. COLI MR 14 SDWIS / AZ0414082 / 3014
2019 Cryptosporidium MR 12 SDWIS / AZ0414082 / 3015
2019 Turbidity MR 12 SDWIS / AZ0414082 / 0100
2019 Lead and Copper Rule MR 2 SDWIS / AZ0414082 / 5000
2018 Nitrate MR 15 SDWIS / AZ0414082 / 1040
2018 DICHLOROMETHANE MR 6 SDWIS / AZ0414082 / 2964
2018 o-Dichlorobenzene MR 6 SDWIS / AZ0414082 / 2968

How Usmc Yuma Main System Compares

Cross-reference this system's record against state averages and the federal MCL framework for context.

Metric Usmc Yuma Main System Arizona avg Federal benchmark
Total violations 350 153.3 SDWA compliance, any non-zero count is a recorded breach
Health-based violations 13 10.5 Indicates a contaminant exceeded a federal MCL
PFAS detection 1 compound 95.4% EPA final rule (2024): PFOA/PFOS MCL = 4.0 ppt
Population served 6,324 4,904 Sizing context for compliance burden

Sources: EPA SDWIS and EPA National Primary Drinking Water Regulations (40 CFR Part 141). State averages computed across 1,493 regulated public water systems in Arizona.

Federal MCL reference, Safe Drinking Water Act thresholds
Contaminant Federal MCL / Action Level Note
Lead 0 mg/L (Action Level: 0.015 mg/L) Lead and Copper Rule treatment technique
Arsenic 0.010 mg/L (10 ppb) Health-based MCL since 2006
Total Coliform Treatment technique (RTCR) Indicator organism, monitoring trigger
PFOA / PFOS (PFAS) 4.0 ppt each (final 2024 rule) Compliance deadline 2029 (EPA proposed extending to 2031, not yet final as of May 2026)
Nitrate (as N) 10 mg/L Acute health risk for infants

Frequently Asked Questions

Is Usmc Yuma Main System water safe to drink?
Usmc Yuma Main System (PWS ID: AZ0414082) has 350 recorded violations in the EPA SDWIS database. PFAS contamination has been detected in UCMR5 testing, with 1 PFAS compound found. This system serves 6,324 people using Surface Water sources.
How many people does Usmc Yuma Main System serve?
Usmc Yuma Main System serves 6,324 people in Yuma, Arizona. It is a Federal-owned system using Surface Water water sources with 1,000 service connections.
What type of violations does Usmc Yuma Main System have?
Usmc Yuma Main System has 350 total violations: 13 health-based violations (MCL exceedances or treatment failures), 311 monitoring/reporting violations, and 8 treatment technique violations. Health-based violations indicate contaminant levels exceeded EPA safe limits.
Has PFAS been detected in Usmc Yuma Main System water?
Yes. UCMR5 testing detected 1 PFAS compound in Usmc Yuma Main System's water supply: PFHxS. PFAS are persistent "forever chemicals" that do not break down in the environment.
What water source does Usmc Yuma Main System use?
Usmc Yuma Main System uses Surface Water as its primary water source. It is classified as a Community Water System (CWS), serving residential populations year-round.
Where does this data come from?
All data comes from the EPA Safe Drinking Water Information System (SDWIS) and the UCMR5 PFAS monitoring program. SDWIS tracks compliance for all public water systems regulated under the Safe Drinking Water Act.
Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. PFAS data from EPA UCMR5 monitoring program (2023-2025). This data is provided for informational purposes only.
Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater Editorial

Every figure on PlainWater is rendered directly from EPA SDWIS drinking-water data, no number is typed in by an editor. This system's figures are rendered directly from EPA SDWIS data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.