PlainWater

Community Water System · PWS AL0001796

Dekalb-Jackson Water Supply District

Ider, Alabama 35981 - drinking water served from surface water sources to 15,531 people, tracked in EPA SDWIS and UCMR5.

15,531
People served
101
EPA violations
76
Health-based
2 PFAS
UCMR5 result

The verdict

EPA records 101 drinking-water violations at Dekalb-Jackson Water Supply District, 75% of them health-based - above the Alabama per-system average, and UCMR5 testing detected 2 PFAS compounds.

101
Total EPA violations on record
75%
Health-based (MCL / treatment failure)
15,531
People served by this system
2
PFAS compounds detected (UCMR5)

Water Quality Snapshot: Dekalb-Jackson Water Supply District

Dekalb-Jackson Water Supply District is a local-owned community water system that delivers drinking water to 15,531 residents in Ider, Alabama (Jackson County) through 5,178 service connections. Its water is drawn from surface water sources. EPA's Safe Drinking Water Information System records 101 total violations for this system , of which 76 (75%) are health-based, meaning a contaminant exceeded an EPA Maximum Contaminant Level or a required treatment technique failed. A further 25 monitoring and reporting violations are on file. The most recent violation on record dates to 2025.

The most frequently cited contaminant at this system is Total Haloacetic Acids (HAA5), recorded in 53 violations (MCL, health-based). Under EPA's UCMR5 PFAS monitoring program, 2 PFAS compounds were detected in samples collected from this system, with a maximum reported concentration of 8.1 ppt (parts per trillion). PFAS are persistent synthetic chemicals linked to health effects at very low exposure levels.

Across Alabama, EPA tracks 562 public water systems serving 6,193,356 people, with 40,486 cumulative violations and 3,786 health-based violations on record. About 99% of systems in the state carry at least one violation, and state-wide the average per system is 72 violations. Statewide, 157 of 306 UCMR5-tested systems have reported PFAS detections (51.3%).

Dekalb-Jackson Water Supply District's 101 violations sit above the Alabama average.

All figures above are sourced directly from EPA SDWIS and UCMR5 public data releases and are updated as EPA publishes new reporting cycles.

PFAS Detected

2 PFAS "forever chemicals" detected in testing under EPA's UCMR5 monitoring program.

Population Served
15,531
Total Violations
101
Health-Based Violations
76
Water Source
Surface Water

System Details

System Type
Community
Owner Type
Local
Connections
5,178
County
Jackson
School/Daycare
No
MCL Violations
76
Monitoring Violations
25
Treatment Tech Violations
0

Violation History

Contaminant violations recorded by EPA.

Contaminant Category Count Latest
Total Haloacetic Acids (HAA5) MCL 53 2025
TTHM MCL 23 2025
LASSO MR 2 2023
CARBON, TOTAL MR 2 2022
1,2,4-Trichlorobenzene MR 1 2009
1,1,1-Trichloroethane MR 1 2009
1,2-Dichloropropane MR 1 2009
Tetrachloroethylene MR 1 2009
Benzene MR 1 2009
Toluene MR 1 2009
Ethylbenzene MR 1 2009
Styrene MR 1 2009
Xylenes, Total MR 1 2009
DICHLOROMETHANE MR 1 2009
p-Dichlorobenzene MR 1 2009
Vinyl chloride MR 1 2009
1,2-Dichloroethane MR 1 2009
1,1-Dichloroethylene MR 1 2009
trans-1,2-Dichloroethylene MR 1 2009
Carbon tetrachloride MR 1 2009
CHLOROBENZENE MR 1 2009
1,1,2-Trichloroethane MR 1 2009
cis-1,2-Dichloroethylene MR 1 2009
Trichloroethylene MR 1 2009
o-Dichlorobenzene MR 1 2009

PFAS Testing Results (UCMR5)

Results from EPA's Fifth Unregulated Contaminant Monitoring Rule. 5 of 116 samples detected PFAS.

Contaminant Date Result MRL Status
PFHpA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFHpS 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFPeS 7/10/2024 <4.00 ppt 4.00 ppt Not Detected
NFDHA 7/10/2024 <20.00 ppt 20.00 ppt Not Detected
PFEESA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFMBA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
NMeFOSAA 7/10/2024 <6.00 ppt 6.00 ppt Not Detected
PFPeA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFMPA 7/10/2024 <4.00 ppt 4.00 ppt Not Detected
8:2 FTS 7/10/2024 <5.00 ppt 5.00 ppt Not Detected
4:2 FTS 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFBA 7/10/2024 8.10 ppt 5.00 ppt Detected
PFBS 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
11Cl-PF3OUdS 7/10/2024 <5.00 ppt 5.00 ppt Not Detected
NEtFOSAA 7/10/2024 <5.00 ppt 5.00 ppt Not Detected
PFTrDA 7/10/2024 <7.00 ppt 7.00 ppt Not Detected
PFTA 7/10/2024 <8.00 ppt 8.00 ppt Not Detected
HFPO-DA 7/10/2024 <5.00 ppt 5.00 ppt Not Detected
6:2 FTS 7/10/2024 <5.00 ppt 5.00 ppt Not Detected
9Cl-PF3ONS 7/10/2024 <2.00 ppt 2.00 ppt Not Detected
PFHxS 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFUnA 7/10/2024 <2.00 ppt 2.00 ppt Not Detected
PFHxA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFDA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
PFOA 7/10/2024 <4.00 ppt 4.00 ppt Not Detected
PFOS 7/10/2024 <4.00 ppt 4.00 ppt Not Detected
PFNA 7/10/2024 <4.00 ppt 4.00 ppt Not Detected
ADONA 7/10/2024 <3.00 ppt 3.00 ppt Not Detected
HFPO-DA 4/3/2024 <5.00 ppt 5.00 ppt Not Detected
ADONA 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
9Cl-PF3ONS 4/3/2024 <2.00 ppt 2.00 ppt Not Detected
11Cl-PF3OUdS 4/3/2024 <5.00 ppt 5.00 ppt Not Detected
PFNA 4/3/2024 <4.00 ppt 4.00 ppt Not Detected
PFDA 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxS 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
PFOA 4/3/2024 <4.00 ppt 4.00 ppt Not Detected
PFOS 4/3/2024 <4.00 ppt 4.00 ppt Not Detected
PFBA 4/3/2024 5.10 ppt 5.00 ppt Detected
PFPeS 4/3/2024 <4.00 ppt 4.00 ppt Not Detected
PFHpA 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
PFHxA 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
PFHpS 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
PFDoA 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
PFBS 4/3/2024 7.70 ppt 3.00 ppt Detected
NMeFOSAA 4/3/2024 <6.00 ppt 6.00 ppt Not Detected
NEtFOSAA 4/3/2024 <5.00 ppt 5.00 ppt Not Detected
PFTrDA 4/3/2024 <7.00 ppt 7.00 ppt Not Detected
PFEESA 4/3/2024 <3.00 ppt 3.00 ppt Not Detected
6:2 FTS 4/3/2024 <5.00 ppt 5.00 ppt Not Detected

Verify This Water System

The figures above are aggregated from EPA's public databases. To verify the underlying records, or to file a complaint, request a Consumer Confidence Report, or check current monitoring status, go directly to the federal and state regulators that enforce the Safe Drinking Water Act for Dekalb-Jackson Water Supply District.

Federal Source of Truth

EPA SDWIS, Federal Reports

EPA's Safe Drinking Water Information System (SDWIS) holds the federal compliance record for every regulated public water system. Open the system-level report by PWS ID:

View PWS ID AL0001796 on SDWIS

Source: EPA SDWIS Federal Reports Search

State Regulator

Alabama Drinking Water Authority

Alabama's primacy agency administers the Safe Drinking Water Act locally. Search EPA SDWIS for the current state contact, or use the state's public health or environment department portal.

Find AL regulator via EPA SDWIS

Violation Timeline

Each row links to the EPA SDWIS public record for verification. Cross-reference the contaminant code on EPA's federal report to see violation dates, return-to-compliance status, and enforcement actions.

Year (latest) Contaminant Category Count EPA Record
2025 Total Haloacetic Acids (HAA5) MCL 53 SDWIS / AL0001796 / 2456
2025 TTHM MCL 23 SDWIS / AL0001796 / 2950
2023 LASSO MR 2 SDWIS / AL0001796 / 2051
2022 CARBON, TOTAL MR 2 SDWIS / AL0001796 / 2920
2009 1,2,4-Trichlorobenzene MR 1 SDWIS / AL0001796 / 2378
2009 1,1,1-Trichloroethane MR 1 SDWIS / AL0001796 / 2981
2009 1,2-Dichloropropane MR 1 SDWIS / AL0001796 / 2983
2009 Tetrachloroethylene MR 1 SDWIS / AL0001796 / 2987
2009 Benzene MR 1 SDWIS / AL0001796 / 2990
2009 Toluene MR 1 SDWIS / AL0001796 / 2991
2009 Ethylbenzene MR 1 SDWIS / AL0001796 / 2992
2009 Styrene MR 1 SDWIS / AL0001796 / 2996
2009 Xylenes, Total MR 1 SDWIS / AL0001796 / 2955
2009 DICHLOROMETHANE MR 1 SDWIS / AL0001796 / 2964
2009 p-Dichlorobenzene MR 1 SDWIS / AL0001796 / 2969

How Dekalb-Jackson Water Supply District Compares

Cross-reference this system's record against state averages and the federal MCL framework for context.

Metric Dekalb-Jackson Water Supply District Alabama avg Federal benchmark
Total violations 101 72 SDWA compliance, any non-zero count is a recorded breach
Health-based violations 76 6.7 Indicates a contaminant exceeded a federal MCL
PFAS detection 2 compounds 51.3% EPA final rule (2024): PFOA/PFOS MCL = 4.0 ppt
Population served 15,531 11,020 Sizing context for compliance burden

Sources: EPA SDWIS and EPA National Primary Drinking Water Regulations (40 CFR Part 141). State averages computed across 562 regulated public water systems in Alabama.

Federal MCL reference, Safe Drinking Water Act thresholds
Contaminant Federal MCL / Action Level Note
Lead 0 mg/L (Action Level: 0.015 mg/L) Lead and Copper Rule treatment technique
Arsenic 0.010 mg/L (10 ppb) Health-based MCL since 2006
Total Coliform Treatment technique (RTCR) Indicator organism, monitoring trigger
PFOA / PFOS (PFAS) 4.0 ppt each (final 2024 rule) Compliance deadline 2029 (EPA proposed extending to 2031, not yet final as of May 2026)
Nitrate (as N) 10 mg/L Acute health risk for infants

Frequently Asked Questions

Is Dekalb-Jackson Water Supply District water safe to drink?
Dekalb-Jackson Water Supply District (PWS ID: AL0001796) has 101 recorded violations in the EPA SDWIS database. PFAS contamination has been detected in UCMR5 testing, with 2 PFAS compounds found. This system serves 15,531 people using Surface Water sources.
How many people does Dekalb-Jackson Water Supply District serve?
Dekalb-Jackson Water Supply District serves 15,531 people in Ider, Alabama. It is a Local-owned system using Surface Water water sources with 5,178 service connections.
What type of violations does Dekalb-Jackson Water Supply District have?
Dekalb-Jackson Water Supply District has 101 total violations: 76 health-based violations (MCL exceedances or treatment failures), 25 monitoring/reporting violations, and 0 treatment technique violations. Health-based violations indicate contaminant levels exceeded EPA safe limits.
Has PFAS been detected in Dekalb-Jackson Water Supply District water?
Yes. UCMR5 testing detected 2 PFAS compounds in Dekalb-Jackson Water Supply District's water supply: PFBA, PFBS. PFAS are persistent "forever chemicals" that do not break down in the environment.
What water source does Dekalb-Jackson Water Supply District use?
Dekalb-Jackson Water Supply District uses Surface Water as its primary water source. It is classified as a Community Water System (CWS), serving residential populations year-round.
Where does this data come from?
All data comes from the EPA Safe Drinking Water Information System (SDWIS) and the UCMR5 PFAS monitoring program. SDWIS tracks compliance for all public water systems regulated under the Safe Drinking Water Act.
Data Sources: EPA Safe Drinking Water Information System (SDWIS), Q4 2025. PFAS data from EPA UCMR5 monitoring program (2023-2025). This data is provided for informational purposes only.
Data sourced from EPA SDWIS and UCMR5 PFAS monitoring data. See our methodology for details. Retrieved and formatted by PlainWater Editorial

Every figure on PlainWater is rendered directly from EPA SDWIS drinking-water data, no number is typed in by an editor. This system's figures are rendered directly from EPA SDWIS data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.